- function [ avw, machine ] = avw_img_read(fileprefix,IMGorient,machine,verbose)
- % avw_img_read - read Analyze format data image (*.img)
- %
- % [ avw, machine ] = avw_img_read(fileprefix,[orient],[machine],[verbose])
- %
- % fileprefix - a string, the filename without the .img extension
- %
- % orient - read a specified orientation, integer values:
- %
- % '', use header history orient field
- % 0, transverse unflipped (LAS*)
- % 1, coronal unflipped (LA*S)
- % 2, sagittal unflipped (L*AS)
- % 3, transverse flipped (LPS*)
- % 4, coronal flipped (LA*I)
- % 5, sagittal flipped (L*AI)
- %
- % where * follows the slice dimension and letters indicate +XYZ
- % orientations (L left, R right, A anterior, P posterior,
- % I inferior, & S superior).
- %
- % Some files may contain data in the 3-5 orientations, but this
- % is unlikely. For more information about orientation, see the
- % documentation at the end of this .m file. See also the
- % AVW_FLIP function for orthogonal reorientation.
- %
- % machine - a string, see machineformat in fread for details.
- % The default here is 'ieee-le' but the routine
- % will automatically switch between little and big
- % endian to read any such Analyze header. It
- % reports the appropriate machine format and can
- % return the machine value.
- %
- % verbose - the default is to output processing information to the command
- % window. If verbose = 0, this will not happen.
- %
- % Returned values:
- %
- % avw.hdr - a struct with image data parameters.
- % avw.img - a 3D matrix of image data (double precision).
- %
- % A returned 3D matrix will correspond with the
- % default ANALYZE coordinate system, which
- % is Left-handed:
- %
- % X-Y plane is Transverse
- % X-Z plane is Coronal
- % Y-Z plane is Sagittal
- %
- % X axis runs from patient right (low X) to patient Left (high X)
- % Y axis runs from posterior (low Y) to Anterior (high Y)
- % Z axis runs from inferior (low Z) to Superior (high Z)
- %
- % The function can read a 4D Analyze volume, but only if it is in the
- % axial unflipped orientation.
- %
- % See also: avw_hdr_read (called by this function),
- % avw_view, avw_write, avw_img_write, avw_flip
- %
- % $Revision: 2885 $ $Date: 2009/01/14 09:24:45 $
- % Licence: GNU GPL, no express or implied warranties
- % History: 05/2002, Darren.Weber@flinders.edu.au
- % The Analyze format is copyright
- % (c) Copyright, 1986-1995
- % Biomedical Imaging Resource, Mayo Foundation
- % 01/2003, Darren.Weber@flinders.edu.au
- % - adapted for matlab v5
- % - revised all orientation information and handling
- % after seeking further advice from AnalyzeDirect.com
- % 03/2003, Darren.Weber@flinders.edu.au
- % - adapted for -ve pixdim values (non standard Analyze)
- % 07/2004, chodkowski@kennedykrieger.org, added ability to
- % read volumes with dimensionality greather than 3.
- % a >3D volume cannot be flipped. and error is thrown if a volume of
- % greater than 3D (ie, avw.hdr.dime.dim(1) > 3) requests a data flip
- % (ie, avw.hdr.hist.orient ~= 0 ). i pulled the transfer of read-in
- % data (tmp) to avw.img out of any looping mechanism. looping is not
- % necessary as the data is already in its correct orientation. using
- % 'reshape' rather than looping should be faster but, more importantly,
- % it allows the reading in of N-D volumes. See lines 270-280.
- %%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
- % check if SPM2 is in path and if not add
- hastoolbox('SPM2',1);
- if ~exist('IMGorient','var'), IMGorient = ''; end
- if ~exist('machine','var'), machine = 'ieee-le'; end
- if ~exist('verbose','var'), verbose = 1; end
- if isempty(IMGorient), IMGorient = ''; end
- if isempty(machine), machine = 'ieee-le'; end
- if isempty(verbose), verbose = 1; end
- if ~exist('fileprefix','var'),
- msg = sprintf('...no input fileprefix - see help avw_img_read\n\n');
- error(msg);
- end
- if findstr('.hdr',fileprefix),
- fileprefix = strrep(fileprefix,'.hdr','');
- end
- if findstr('.img',fileprefix),
- fileprefix = strrep(fileprefix,'.img','');
- end
- % MAIN
- % Read the file header
- [ avw, machine ] = avw_hdr_read(fileprefix,machine,verbose);
- avw = read_image(avw,IMGorient,machine,verbose);
- return
- %%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
- %%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
- function [ avw ] = read_image(avw,IMGorient,machine,verbose)
- fid = fopen(sprintf('%s.img',avw.fileprefix),'r',machine);
- if fid < 0,
- msg = sprintf('...cannot open file %s.img\n\n',avw.fileprefix);
- error(msg);
- end
- if verbose,
- ver = '[$Revision: 2885 $]';
- fprintf('\nAVW_IMG_READ [v%s]\n',ver(12:16)); tic;
- end
- % short int bitpix; /* Number of bits per pixel; 1, 8, 16, 32, or 64. */
- % short int datatype /* Datatype for this image set */
- % /*Acceptable values for datatype are*/
- % #define DT_NONE 0
- % #define DT_UNKNOWN 0 /*Unknown data type*/
- % #define DT_BINARY 1 /*Binary ( 1 bit per voxel)*/
- % #define DT_UNSIGNED_CHAR 2 /*Unsigned character ( 8 bits per voxel)*/
- % #define DT_SIGNED_SHORT 4 /*Signed short (16 bits per voxel)*/
- % #define DT_SIGNED_INT 8 /*Signed integer (32 bits per voxel)*/
- % #define DT_FLOAT 16 /*Floating point (32 bits per voxel)*/
- % #define DT_COMPLEX 32 /*Complex (64 bits per voxel; 2 floating point numbers)/*
- % #define DT_DOUBLE 64 /*Double precision (64 bits per voxel)*/
- % #define DT_RGB 128 /*A Red-Green-Blue datatype*/
- % #define DT_ALL 255 /*Undocumented*/
- switch double(avw.hdr.dime.bitpix),
- case 1, precision = 'bit1';
- case 8, precision = 'uchar';
- case 16, precision = 'int16';
- case 32,
- if isequal(avw.hdr.dime.datatype, 8), precision = 'int32';
- else precision = 'single';
- end
- case 64, precision = 'double';
- otherwise,
- precision = 'uchar';
- if verbose, fprintf('...precision undefined in header, using ''uchar''\n'); end
- end
- % read the whole .img file into matlab (faster)
- if verbose,
- fprintf('...reading %s Analyze %s image format.\n',machine,precision);
- end
- fseek(fid,0,'bof');
- % adjust for matlab version
- ver = version;
- ver = str2num(ver(1));
- if ver < 6,
- tmp = fread(fid,inf,sprintf('%s',precision));
- else,
- tmp = fread(fid,inf,sprintf('%s=>double',precision));
- end
- fclose(fid);
- % Update the global min and max values
- avw.hdr.dime.glmax = max(double(tmp));
- avw.hdr.dime.glmin = min(double(tmp));
- %---------------------------------------------------------------
- % Now partition the img data into xyz
- % --- first figure out the size of the image
- % short int dim[ ]; /* Array of the image dimensions */
- %
- % dim[0] Number of dimensions in database; usually 4.
- % dim[1] Image X dimension; number of pixels in an image row.
- % dim[2] Image Y dimension; number of pixel rows in slice.
- % dim[3] Volume Z dimension; number of slices in a volume.
- % dim[4] Time points; number of volumes in database.
- PixelDim = double(avw.hdr.dime.dim(2));
- RowDim = double(avw.hdr.dime.dim(3));
- SliceDim = double(avw.hdr.dime.dim(4));
- TimeDim = double(avw.hdr.dime.dim(5));
- PixelSz = double(avw.hdr.dime.pixdim(2));
- RowSz = double(avw.hdr.dime.pixdim(3));
- SliceSz = double(avw.hdr.dime.pixdim(4));
- TimeSz = double(avw.hdr.dime.pixdim(5));
- % ---- NON STANDARD ANALYZE...
- % Some Analyze files have been found to set -ve pixdim values, eg
- % the MNI template avg152T1_brain in the FSL etc/standard folder,
- % perhaps to indicate flipped orientation? If so, this code below
- % will NOT handle the flip correctly!
- if PixelSz < 0,
- warning('X pixdim < 0 !!! resetting to abs(avw.hdr.dime.pixdim(2))');
- PixelSz = abs(PixelSz);
- avw.hdr.dime.pixdim(2) = single(PixelSz);
- end
- if RowSz < 0,
- warning('Y pixdim < 0 !!! resetting to abs(avw.hdr.dime.pixdim(3))');
- RowSz = abs(RowSz);
- avw.hdr.dime.pixdim(3) = single(RowSz);
- end
- if SliceSz < 0,
- warning('Z pixdim < 0 !!! resetting to abs(avw.hdr.dime.pixdim(4))');
- SliceSz = abs(SliceSz);
- avw.hdr.dime.pixdim(4) = single(SliceSz);
- end
- % ---- END OF NON STANDARD ANALYZE
- % --- check the orientation specification and arrange img accordingly
- if ~isempty(IMGorient),
- if ischar(IMGorient),
- avw.hdr.hist.orient = uint8(str2num(IMGorient));
- else
- avw.hdr.hist.orient = uint8(IMGorient);
- end
- end,
- if isempty(avw.hdr.hist.orient),
- msg = [ '...unspecified avw.hdr.hist.orient, using default 0\n',...
- ' (check image and try explicit IMGorient option).\n'];
- fprintf(msg);
- avw.hdr.hist.orient = uint8(0);
- end
- % --- check if the orientation is to be flipped for a volume with more
- % --- than 3 dimensions. this logic is currently unsupported so throw
- % --- an error. volumes of any dimensionality may be read in *only* as
- % --- unflipped, ie, avw.hdr.hist.orient == 0
- if ( TimeDim > 1 ) && (avw.hdr.hist.orient ~= 0 ),
- msg = [ 'ERROR: This volume has more than 3 dimensions *and* ', ...
- 'requires flipping the data. Flipping is not supported ', ...
- 'for volumes with dimensionality greater than 3. Set ', ...
- 'avw.hdr.hist.orient = 0 and flip your volume after ', ...
- 'calling this function' ];
- msg = sprintf( '%s (%s).', msg, mfilename );
- error( msg );
- end
- switch double(avw.hdr.hist.orient),
-
- case 0, % transverse unflipped
-
- % orient = 0: The primary orientation of the data on disk is in the
- % transverse plane relative to the object scanned. Most commonly, the fastest
- % moving index through the voxels that are part of this transverse image would
- % span the right-left extent of the structure imaged, with the next fastest
- % moving index spanning the posterior-anterior extent of the structure. This
- % 'orient' flag would indicate to Analyze that this data should be placed in
- % the X-Y plane of the 3D Analyze Coordinate System, with the Z dimension
- % being the slice direction.
-
- % For the 'transverse unflipped' type, the voxels are stored with
- % Pixels in 'x' axis (varies fastest) - from patient right to left
- % Rows in 'y' axis - from patient posterior to anterior
- % Slices in 'z' axis - from patient inferior to superior
-
- if verbose, fprintf('...reading axial unflipped orientation\n'); end
-
- % -- This code will handle nD files
- dims = double( avw.hdr.dime.dim(2:end) );
- % replace dimensions of 0 with 1 to be used in reshape
- idx = find( dims == 0 );
- dims( idx ) = 1;
- avw.img = reshape( tmp, dims );
-
- % -- The code above replaces this
- % avw.img = zeros(PixelDim,RowDim,SliceDim);
- %
- % n = 1;
- % x = 1:PixelDim;
- % for z = 1:SliceDim,
- % for y = 1:RowDim,
- % % load Y row of X values into Z slice avw.img
- % avw.img(x,y,z) = tmp(n:n+(PixelDim-1));
- % n = n + PixelDim;
- % end
- % end
-
-
- % no need to rearrange avw.hdr.dime.dim or avw.hdr.dime.pixdim
-
-
- case 1, % coronal unflipped
-
- % orient = 1: The primary orientation of the data on disk is in the coronal
- % plane relative to the object scanned. Most commonly, the fastest moving
- % index through the voxels that are part of this coronal image would span the
- % right-left extent of the structure imaged, with the next fastest moving
- % index spanning the inferior-superior extent of the structure. This 'orient'
- % flag would indicate to Analyze that this data should be placed in the X-Z
- % plane of the 3D Analyze Coordinate System, with the Y dimension being the
- % slice direction.
-
- % For the 'coronal unflipped' type, the voxels are stored with
- % Pixels in 'x' axis (varies fastest) - from patient right to left
- % Rows in 'z' axis - from patient inferior to superior
- % Slices in 'y' axis - from patient posterior to anterior
-
- if verbose, fprintf('...reading coronal unflipped orientation\n'); end
-
- avw.img = zeros(PixelDim,SliceDim,RowDim);
-
- n = 1;
- x = 1:PixelDim;
- for y = 1:SliceDim,
- for z = 1:RowDim,
- % load Z row of X values into Y slice avw.img
- avw.img(x,y,z) = tmp(n:n+(PixelDim-1));
- n = n + PixelDim;
- end
- end
-
- % rearrange avw.hdr.dime.dim or avw.hdr.dime.pixdim
- avw.hdr.dime.dim(2:4) = int16([PixelDim,SliceDim,RowDim]);
- avw.hdr.dime.pixdim(2:4) = single([PixelSz,SliceSz,RowSz]);
-
-
- case 2, % sagittal unflipped
-
- % orient = 2: The primary orientation of the data on disk is in the sagittal
- % plane relative to the object scanned. Most commonly, the fastest moving
- % index through the voxels that are part of this sagittal image would span the
- % posterior-anterior extent of the structure imaged, with the next fastest
- % moving index spanning the inferior-superior extent of the structure. This
- % 'orient' flag would indicate to Analyze that this data should be placed in
- % the Y-Z plane of the 3D Analyze Coordinate System, with the X dimension
- % being the slice direction.
-
- % For the 'sagittal unflipped' type, the voxels are stored with
- % Pixels in 'y' axis (varies fastest) - from patient posterior to anterior
- % Rows in 'z' axis - from patient inferior to superior
- % Slices in 'x' axis - from patient right to left
-
- if verbose, fprintf('...reading sagittal unflipped orientation\n'); end
-
- avw.img = zeros(SliceDim,PixelDim,RowDim);
-
- n = 1;
- y = 1:PixelDim; % posterior to anterior (fastest)
-
- for x = 1:SliceDim, % right to left (slowest)
- for z = 1:RowDim, % inferior to superior
-
- % load Z row of Y values into X slice avw.img
- avw.img(x,y,z) = tmp(n:n+(PixelDim-1));
- n = n + PixelDim;
- end
- end
-
- % rearrange avw.hdr.dime.dim or avw.hdr.dime.pixdim
- avw.hdr.dime.dim(2:4) = int16([SliceDim,PixelDim,RowDim]);
- avw.hdr.dime.pixdim(2:4) = single([SliceSz,PixelSz,RowSz]);
-
-
- %--------------------------------------------------------------------------------
- % Orient values 3-5 have the second index reversed in order, essentially
- % 'flipping' the images relative to what would most likely become the vertical
- % axis of the displayed image.
- %--------------------------------------------------------------------------------
-
- case 3, % transverse/axial flipped
-
- % orient = 3: The primary orientation of the data on disk is in the
- % transverse plane relative to the object scanned. Most commonly, the fastest
- % moving index through the voxels that are part of this transverse image would
- % span the right-left extent of the structure imaged, with the next fastest
- % moving index spanning the *anterior-posterior* extent of the structure. This
- % 'orient' flag would indicate to Analyze that this data should be placed in
- % the X-Y plane of the 3D Analyze Coordinate System, with the Z dimension
- % being the slice direction.
-
- % For the 'transverse flipped' type, the voxels are stored with
- % Pixels in 'x' axis (varies fastest) - from patient right to Left
- % Rows in 'y' axis - from patient anterior to Posterior *
- % Slices in 'z' axis - from patient inferior to Superior
-
- if verbose, fprintf('...reading axial flipped (+Y from Anterior to Posterior)\n'); end
-
- avw.img = zeros(PixelDim,RowDim,SliceDim);
-
- n = 1;
- x = 1:PixelDim;
- for z = 1:SliceDim,
- for y = RowDim:-1:1, % flip in Y, read A2P file into P2A 3D matrix
-
- % load a flipped Y row of X values into Z slice avw.img
- avw.img(x,y,z) = tmp(n:n+(PixelDim-1));
- n = n + PixelDim;
- end
- end
-
- % no need to rearrange avw.hdr.dime.dim or avw.hdr.dime.pixdim
-
-
- case 4, % coronal flipped
-
- % orient = 4: The primary orientation of the data on disk is in the coronal
- % plane relative to the object scanned. Most commonly, the fastest moving
- % index through the voxels that are part of this coronal image would span the
- % right-left extent of the structure imaged, with the next fastest moving
- % index spanning the *superior-inferior* extent of the structure. This 'orient'
- % flag would indicate to Analyze that this data should be placed in the X-Z
- % plane of the 3D Analyze Coordinate System, with the Y dimension being the
- % slice direction.
-
- % For the 'coronal flipped' type, the voxels are stored with
- % Pixels in 'x' axis (varies fastest) - from patient right to Left
- % Rows in 'z' axis - from patient superior to Inferior*
- % Slices in 'y' axis - from patient posterior to Anterior
-
- if verbose, fprintf('...reading coronal flipped (+Z from Superior to Inferior)\n'); end
-
- avw.img = zeros(PixelDim,SliceDim,RowDim);
-
- n = 1;
- x = 1:PixelDim;
- for y = 1:SliceDim,
- for z = RowDim:-1:1, % flip in Z, read S2I file into I2S 3D matrix
-
- % load a flipped Z row of X values into Y slice avw.img
- avw.img(x,y,z) = tmp(n:n+(PixelDim-1));
- n = n + PixelDim;
- end
- end
-
- % rearrange avw.hdr.dime.dim or avw.hdr.dime.pixdim
- avw.hdr.dime.dim(2:4) = int16([PixelDim,SliceDim,RowDim]);
- avw.hdr.dime.pixdim(2:4) = single([PixelSz,SliceSz,RowSz]);
-
-
- case 5, % sagittal flipped
-
- % orient = 5: The primary orientation of the data on disk is in the sagittal
- % plane relative to the object scanned. Most commonly, the fastest moving
- % index through the voxels that are part of this sagittal image would span the
- % posterior-anterior extent of the structure imaged, with the next fastest
- % moving index spanning the *superior-inferior* extent of the structure. This
- % 'orient' flag would indicate to Analyze that this data should be placed in
- % the Y-Z plane of the 3D Analyze Coordinate System, with the X dimension
- % being the slice direction.
-
- % For the 'sagittal flipped' type, the voxels are stored with
- % Pixels in 'y' axis (varies fastest) - from patient posterior to Anterior
- % Rows in 'z' axis - from patient superior to Inferior*
- % Slices in 'x' axis - from patient right to Left
-
- if verbose, fprintf('...reading sagittal flipped (+Z from Superior to Inferior)\n'); end
-
- avw.img = zeros(SliceDim,PixelDim,RowDim);
-
- n = 1;
- y = 1:PixelDim;
-
- for x = 1:SliceDim,
- for z = RowDim:-1:1, % flip in Z, read S2I file into I2S 3D matrix
-
- % load a flipped Z row of Y values into X slice avw.img
- avw.img(x,y,z) = tmp(n:n+(PixelDim-1));
- n = n + PixelDim;
- end
- end
-
- % rearrange avw.hdr.dime.dim or avw.hdr.dime.pixdim
- avw.hdr.dime.dim(2:4) = int16([SliceDim,PixelDim,RowDim]);
- avw.hdr.dime.pixdim(2:4) = single([SliceSz,PixelSz,RowSz]);
-
- otherwise
-
- error('unknown value in avw.hdr.hist.orient, try explicit IMGorient option.');
-
- end
- if verbose, t=toc; fprintf('...done (%5.2f sec).\n\n',t); end
- return
- % This function attempts to read the orientation of the
- % Analyze file according to the hdr.hist.orient field of the
- % header. Unfortunately, this field is optional and not
- % all programs will set it correctly, so there is no guarantee,
- % that the data loaded will be correctly oriented. If necessary,
- % experiment with the 'orient' option to read the .img
- % data into the 3D matrix of avw.img as preferred.
- %
- % (Conventions gathered from e-mail with support@AnalyzeDirect.com)
- %
- % 0 transverse unflipped
- % X direction first, progressing from patient right to left,
- % Y direction second, progressing from patient posterior to anterior,
- % Z direction third, progressing from patient inferior to superior.
- % 1 coronal unflipped
- % X direction first, progressing from patient right to left,
- % Z direction second, progressing from patient inferior to superior,
- % Y direction third, progressing from patient posterior to anterior.
- % 2 sagittal unflipped
- % Y direction first, progressing from patient posterior to anterior,
- % Z direction second, progressing from patient inferior to superior,
- % X direction third, progressing from patient right to left.
- % 3 transverse flipped
- % X direction first, progressing from patient right to left,
- % Y direction second, progressing from patient anterior to posterior,
- % Z direction third, progressing from patient inferior to superior.
- % 4 coronal flipped
- % X direction first, progressing from patient right to left,
- % Z direction second, progressing from patient superior to inferior,
- % Y direction third, progressing from patient posterior to anterior.
- % 5 sagittal flipped
- % Y direction first, progressing from patient posterior to anterior,
- % Z direction second, progressing from patient superior to inferior,
- % X direction third, progressing from patient right to left.
- %----------------------------------------------------------------------------
- % From ANALYZE documentation...
- %
- % The ANALYZE coordinate system has an origin in the lower left
- % corner. That is, with the subject lying supine, the coordinate
- % origin is on the right side of the body (x), at the back (y),
- % and at the feet (z). This means that:
- %
- % +X increases from right (R) to left (L)
- % +Y increases from the back (posterior,P) to the front (anterior, A)
- % +Z increases from the feet (inferior,I) to the head (superior, S)
- %
- % The LAS orientation is the radiological convention, where patient
- % left is on the image right. The alternative neurological
- % convention is RAS (also Talairach convention).
- %
- % A major advantage of the Analzye origin convention is that the
- % coordinate origin of each orthogonal orientation (transverse,
- % coronal, and sagittal) lies in the lower left corner of the
- % slice as it is displayed.
- %
- % Orthogonal slices are numbered from one to the number of slices
- % in that orientation. For example, a volume (x, y, z) dimensioned
- % 128, 256, 48 has:
- %
- % 128 sagittal slices numbered 1 through 128 (X)
- % 256 coronal slices numbered 1 through 256 (Y)
- % 48 transverse slices numbered 1 through 48 (Z)
- %
- % Pixel coordinates are made with reference to the slice numbers from
- % which the pixels come. Thus, the first pixel in the volume is
- % referenced p(1,1,1) and not at p(0,0,0).
- %
- % Transverse slices are in the XY plane (also known as axial slices).
- % Sagittal slices are in the ZY plane.
- % Coronal slices are in the ZX plane.
- %
- %----------------------------------------------------------------------------
- %----------------------------------------------------------------------------
- % E-mail from support@AnalyzeDirect.com
- %
- % The 'orient' field in the data_history structure specifies the primary
- % orientation of the data as it is stored in the file on disk. This usually
- % corresponds to the orientation in the plane of acquisition, given that this
- % would correspond to the order in which the data is written to disk by the
- % scanner or other software application. As you know, this field will contain
- % the values:
- %
- % orient = 0 transverse unflipped
- % 1 coronal unflipped
- % 2 sagittal unflipped
- % 3 transverse flipped
- % 4 coronal flipped
- % 5 sagittal flipped
- %
- % It would be vary rare that you would ever encounter any old Analyze 7.5
- % files that contain values of 'orient' which indicate that the data has been
- % 'flipped'. The 'flipped flag' values were really only used internal to
- % Analyze to precondition data for fast display in the Movie module, where the
- % images were actually flipped vertically in order to accommodate the raster
- % paint order on older graphics devices. The only cases you will encounter
- % will have values of 0, 1, or 2.
- %
- % As mentioned, the 'orient' flag only specifies the primary orientation of
- % data as stored in the disk file itself. It has nothing to do with the
- % representation of the data in the 3D Analyze coordinate system, which always
- % has a fixed representation to the data. The meaning of the 'orient' values
- % should be interpreted as follows:
- %
- % orient = 0: The primary orientation of the data on disk is in the
- % transverse plane relative to the object scanned. Most commonly, the fastest
- % moving index through the voxels that are part of this transverse image would
- % span the right-left extent of the structure imaged, with the next fastest
- % moving index spanning the posterior-anterior extent of the structure. This
- % 'orient' flag would indicate to Analyze that this data should be placed in
- % the X-Y plane of the 3D Analyze Coordinate System, with the Z dimension
- % being the slice direction.
- %
- % orient = 1: The primary orientation of the data on disk is in the coronal
- % plane relative to the object scanned. Most commonly, the fastest moving
- % index through the voxels that are part of this coronal image would span the
- % right-left extent of the structure imaged, with the next fastest moving
- % index spanning the inferior-superior extent of the structure. This 'orient'
- % flag would indicate to Analyze that this data should be placed in the X-Z
- % plane of the 3D Analyze Coordinate System, with the Y dimension being the
- % slice direction.
- %
- % orient = 2: The primary orientation of the data on disk is in the sagittal
- % plane relative to the object scanned. Most commonly, the fastest moving
- % index through the voxels that are part of this sagittal image would span the
- % posterior-anterior extent of the structure imaged, with the next fastest
- % moving index spanning the inferior-superior extent of the structure. This
- % 'orient' flag would indicate to Analyze that this data should be placed in
- % the Y-Z plane of the 3D Analyze Coordinate System, with the X dimension
- % being the slice direction.
- %
- % Orient values 3-5 have the second index reversed in order, essentially
- % 'flipping' the images relative to what would most likely become the vertical
- % axis of the displayed image.
- %
- % Hopefully you understand the difference between the indication this 'orient'
- % flag has relative to data stored on disk and the full 3D Analyze Coordinate
- % System for data that is managed as a volume image. As mentioned previously,
- % the orientation of patient anatomy in the 3D Analyze Coordinate System has a
- % fixed orientation relative to each of the orthogonal axes. This orientation
- % is completely described in the information that is attached, but the basics
- % are:
- %
- % Left-handed coordinate system
- %
- % X-Y plane is Transverse
- % X-Z plane is Coronal
- % Y-Z plane is Sagittal
- %
- % X axis runs from patient right (low X) to patient left (high X)
- % Y axis runs from posterior (low Y) to anterior (high Y)
- % Z axis runs from inferior (low Z) to superior (high Z)
- %
- %----------------------------------------------------------------------------
- %----------------------------------------------------------------------------
- % SPM2 NOTES from spm2 webpage: One thing to watch out for is the image
- % orientation. The proper Analyze format uses a left-handed co-ordinate
- % system, whereas Talairach uses a right-handed one. In SPM99, images were
- % flipped at the spatial normalisation stage (from one co-ordinate system
- % to the other). In SPM2b, a different approach is used, so that either a
- % left- or right-handed co-ordinate system is used throughout. The SPM2b
- % program is told about the handedness that the images are stored with by
- % the spm_flip_analyze_images.m function and the defaults.analyze.flip
- % parameter that is specified in the spm_defaults.m file. These files are
- % intended to be customised for each site. If you previously used SPM99
- % and your images were flipped during spatial normalisation, then set
- % defaults.analyze.flip=1. If no flipping took place, then set
- % defaults.analyze.flip=0. Check that when using the Display facility
- % (possibly after specifying some rigid-body rotations) that:
- %
- % The top-left image is coronal with the top (superior) of the head displayed
- % at the top and the left shown on the left. This is as if the subject is viewed
- % from behind.
- %
- % The bottom-left image is axial with the front (anterior) of the head at the
- % top and the left shown on the left. This is as if the subject is viewed from above.
- %
- % The top-right image is sagittal with the front (anterior) of the head at the
- % left and the top of the head shown at the top. This is as if the subject is
- % viewed from the left.
- %----------------------------------------------------------------------------