/opennms-base-assembly/src/main/filtered/etc/events/CRITAPP.events.xml
https://github.com/ajakubo1/opennms · XML · 136 lines · 129 code · 5 blank · 2 comment · 0 complexity · 7bc4fd52c5841a8bba6e39b0c47c44f0 MD5 · raw file
- <!-- Start of auto generated data from MIB: CRITAPP-MIB -->
- <events xmlns="http://xmlns.opennms.org/xsd/eventconf">
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.99.12.29.3</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>1</mevalue>
- </maskelement>
- </mask>
- <uei>uei.opennms.org/vendor/snmpResearch/traps/critAppDown</uei>
- <event-label>CRITAPP-MIB defined trap event: critAppDown</event-label>
- <descr>
- <p>This trap means that the application corresponding to
- critAppIndex changed status to down (exited.)</p><table>
- <tr><td><b>
- critAppName</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- critAppProcID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- critAppLastExitStatus</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- critAppDown trap received
- critAppName=%parm[#1]%
- critAppProcID=%parm[#2]%
- critAppLastExitStatus=%parm[#3]%</p>
- </logmsg>
- <severity>Minor</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%parm[#1]%:%parm[#2]%" alarm-type="1" auto-clean="true"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.99.12.29.3</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>2</mevalue>
- </maskelement>
- </mask>
- <uei>uei.opennms.org/vendor/snmpResearch/traps/critAppUp</uei>
- <event-label>CRITAPP-MIB defined trap event: critAppUp</event-label>
- <descr>
- <p>This trap means that the application corresponding to
- critAppIndex changed status to up.</p><table>
- <tr><td><b>
- critAppName</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- critAppProcID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- critAppUp trap received
- critAppName=%parm[#1]%
- critAppProcID=%parm[#2]%</p>
- </logmsg>
- <severity>Normal</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%parm[#1]%:%parm[#2]%" alarm-type="2" auto-clean="true" clear-key="uei.opennms.org/vendor/snmpResearch/traps/critAppDown:%dpname%:%nodeid%:%parm[#1]%:%parm[#2]%"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.99.12.29.3</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>4</mevalue>
- </maskelement>
- </mask>
- <uei>uei.opennms.org/vendor/snmpResearch/traps/critAppAllRunning</uei>
- <event-label>CRITAPP-MIB defined trap event: critAppAllRunning</event-label>
- <descr>
- <p>This trap means that all applications are up.</p><table></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- critAppAllRunning trap received</p>
- </logmsg>
- <severity>Normal</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%" alarm-type="2" auto-clean="true" clear-key="uei.opennms.org/vendor/snmpResearch/traps/critAppNotAllRunning:%dpname%:%nodeid%"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.99.12.29.3</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>5</mevalue>
- </maskelement>
- </mask>
- <uei>uei.opennms.org/vendor/snmpResearch/traps/critAppNotAllRunning</uei>
- <event-label>CRITAPP-MIB defined trap event: critAppNotAllRunning</event-label>
- <descr>
- <p>This trap means that at least one applications is
- down.</p><table></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- critAppNotAllRunning trap received</p>
- </logmsg>
- <severity>Warning</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%" alarm-type="1" auto-clean="true"/>
- </event>
- </events>
- <!-- End of auto generated data from MIB: CRITAPP-MIB -->