/opennms-base-assembly/src/main/filtered/etc/events/Sentry.events.xml
XML | 6012 lines | 5512 code | 498 blank | 2 comment | 0 complexity | ce01fe99cbf945d00bf841fb0f4e2867 MD5 | raw file
Possible License(s): GPL-2.0, Apache-2.0
- <!-- Start of auto generated data from MIB: Sentry3-MIB -->
- <events xmlns="http://xmlns.opennms.org/xsd/eventconf">
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>1</mevalue>
- </maskelement>
- <varbind>
- <vbnumber>4</vbnumber>
- <vbvalue>0</vbvalue>
- </varbind>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/towerStatusEvent-Normal</uei>
- <event-label>Sentry3-MIB defined trap event: towerStatusEvent-Normal</event-label>
- <descr>
- <p>Tower status event. If enabled, this trap is sent when the
- towerStatus indicates an error state ('noComm', 'fanFail',
- or 'overTemp'). This trap is repeated periodically while the
- towerStatus remains in an error state. If the towerStatus
- returns to a non-error state ('normal'), this trap is sent
- once more with the non-error towerStatus, and then stops
- being repeated.
- While the towerStatus indicates a 'noComm' error state, all
- status and load traps are suppressed for input feeds and
- outlets on the tower.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- towerID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- towerName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- towerStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- normal(0)
- noComm(1)
- fanFail(2)
- overTemp(3)
- </p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: towerStatus is now normal trap received
- systemLocation=%parm[#1]%
- towerID=%parm[#2]%
- towerName=%parm[#3]%
- </logmsg>
- <severity>Normal</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[#2]%:%parm[#3]%" alarm-type="2" clear-key="uei.opennms.org/vendor/ServerTech/traps/towerStatusEvent-Error:%dpname%:%nodeid%:%interface%:%parm[#2]%i:%parm[#3]%" auto-clean="false"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>1</mevalue>
- </maskelement>
- <varbind>
- <vbnumber>4</vbnumber>
- <vbvalue>1</vbvalue>
- </varbind>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/towerStatusEvent-Error</uei>
- <event-label>Sentry3-MIB defined trap event: towerStatusEvent-Error</event-label>
- <descr>
- <p>Tower status event. If enabled, this trap is sent when the
- towerStatus indicates an error state ('noComm', 'fanFail',
- or 'overTemp'). This trap is repeated periodically while the
- towerStatus remains in an error state. If the towerStatus
- returns to a non-error state ('normal'), this trap is sent
- once more with the non-error towerStatus, and then stops
- being repeated.
- While the towerStatus indicates a 'noComm' error state, all
- status and load traps are suppressed for input feeds and
- outlets on the tower.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- towerID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- towerName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- towerStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- normal(0)
- noComm(1)
- fanFail(2)
- overTemp(3)
- </p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: towerStatus comm failure trap received
- systemLocation=%parm[#1]%
- towerID=%parm[#2]%
- towerName=%parm[#3]%
- </logmsg>
- <severity>Minor</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[#2]%:%parm[#3]%" alarm-type="1" auto-clean="false"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>1</mevalue>
- </maskelement>
- <varbind>
- <vbnumber>4</vbnumber>
- <vbvalue>2</vbvalue>
- </varbind>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/towerStatusEvent-Error</uei>
- <event-label>Sentry3-MIB defined trap event: towerStatusEvent-Error</event-label>
- <descr>
- <p>Tower status event. If enabled, this trap is sent when the
- towerStatus indicates an error state ('noComm', 'fanFail',
- or 'overTemp'). This trap is repeated periodically while the
- towerStatus remains in an error state. If the towerStatus
- returns to a non-error state ('normal'), this trap is sent
- once more with the non-error towerStatus, and then stops
- being repeated.
- While the towerStatus indicates a 'noComm' error state, all
- status and load traps are suppressed for input feeds and
- outlets on the tower.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- towerID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- towerName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- towerStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- normal(0)
- noComm(1)
- fanFail(2)
- overTemp(3)
- </p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: towerStatus fan failure trap received
- systemLocation=%parm[#1]%
- towerID=%parm[#2]%
- towerName=%parm[#3]%
- </logmsg>
- <severity>Major</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[#2]%:%parm[#3]%" alarm-type="1" auto-clean="false"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>3</mevalue>
- </maskelement>
- <varbind>
- <vbnumber>4</vbnumber>
- <vbvalue>1</vbvalue>
- </varbind>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/towerStatusEvent-Error</uei>
- <event-label>Sentry3-MIB defined trap event: towerStatusEvent-Error</event-label>
- <descr>
- <p>Tower status event. If enabled, this trap is sent when the
- towerStatus indicates an error state ('noComm', 'fanFail',
- or 'overTemp'). This trap is repeated periodically while the
- towerStatus remains in an error state. If the towerStatus
- returns to a non-error state ('normal'), this trap is sent
- once more with the non-error towerStatus, and then stops
- being repeated.
- While the towerStatus indicates a 'noComm' error state, all
- status and load traps are suppressed for input feeds and
- outlets on the tower.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- towerID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- towerName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- towerStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- normal(0)
- noComm(1)
- fanFail(2)
- overTemp(3)
- </p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: towerStatus over temperature trap received
- systemLocation=%parm[#1]%
- towerID=%parm[#2]%
- towerName=%parm[#3]%
- </logmsg>
- <severity>Major</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[#2]%:%parm[#3]%" alarm-type="1" auto-clean="false"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>1</mevalue>
- </maskelement>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/towerStatusEvent</uei>
- <event-label>Sentry3-MIB defined trap event: towerStatusEvent</event-label>
- <descr>
- <p>Tower status event. If enabled, this trap is sent when the
- towerStatus indicates an error state ('noComm', 'fanFail',
- or 'overTemp'). This trap is repeated periodically while the
- towerStatus remains in an error state. If the towerStatus
- returns to a non-error state ('normal'), this trap is sent
- once more with the non-error towerStatus, and then stops
- being repeated.
- While the towerStatus indicates a 'noComm' error state, all
- status and load traps are suppressed for input feeds and
- outlets on the tower.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- towerID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- towerName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- towerStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- normal(0)
- noComm(1)
- fanFail(2)
- overTemp(3)
- </p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: towerStatusEvent trap received
- systemLocation=%parm[#1]%
- towerID=%parm[#2]%
- towerName=%parm[#3]%
- towerStatus=%parm[#4]%</p>
- </logmsg>
- <severity>Indeterminate</severity>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>2</mevalue>
- </maskelement>
- <varbind>
- <vbnumber>4</vbnumber>
- <vbvalue>0</vbvalue>
- </varbind>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/infeedStatusEvent-Normal</uei>
- <event-label>Sentry3-MIB defined trap event: infeedStatusEvent-Normal</event-label>
- <descr>
- <p>Input feed status event. If enabled, this trap is sent when
- the infeedStatus indicates an error state ('offError',
- 'onError', or 'noComm'). This trap is repeated periodically
- while the infeedStatus remains in an error state. If the
- infeedStatus returns to a non-error state ('off' or 'on'),
- this trap is sent once more with the non-error infeedStatus,
- and then stops being repeated.
- While the infeedStatus indicates an error state, load
- traps are suppressed for the input feed, and, if the
- infeedCapabilities 'failSafe' bit is FALSE, all status and
- load traps are suppressed for outlets on the input feed.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- infeedID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- infeedName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- infeedStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- off(0)
- on(1)
- offWait(2)
- onWait(3)
- offError(4)
- onError(5)
- noComm(6)
- </p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: Input Feed Status off (normal)
- systemLocation=%parm[#1]%
- infeedID=%parm[#2]%
- infeedName=%parm[#3]%
- </logmsg>
- <severity>Normal</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[#2]%:%parm[#3]%" alarm-type="2" clear-key="uei.opennms.org/vendor/ServerTech/traps/infeedStatusEvent-Error:%dpname%:%nodeid%:%interface%:%parm[#2]%i:%parm[#3]%" auto-clean="false"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>2</mevalue>
- </maskelement>
- <varbind>
- <vbnumber>4</vbnumber>
- <vbvalue>1</vbvalue>
- </varbind>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/infeedStatusEvent-Normal</uei>
- <event-label>Sentry3-MIB defined trap event: infeedStatusEvent-Normal</event-label>
- <descr>
- <p>Input feed status event. If enabled, this trap is sent when
- the infeedStatus indicates an error state ('offError',
- 'onError', or 'noComm'). This trap is repeated periodically
- while the infeedStatus remains in an error state. If the
- infeedStatus returns to a non-error state ('off' or 'on'),
- this trap is sent once more with the non-error infeedStatus,
- and then stops being repeated.
- While the infeedStatus indicates an error state, load
- traps are suppressed for the input feed, and, if the
- infeedCapabilities 'failSafe' bit is FALSE, all status and
- load traps are suppressed for outlets on the input feed.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- infeedID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- infeedName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- infeedStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- off(0)
- on(1)
- offWait(2)
- onWait(3)
- offError(4)
- onError(5)
- noComm(6)
- </p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: Input Feed Status on (normal)
- systemLocation=%parm[#1]%
- infeedID=%parm[#2]%
- infeedName=%parm[#3]%
- </logmsg>
- <severity>Normal</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[#2]%:%parm[#3]%" alarm-type="2" clear-key="uei.opennms.org/vendor/ServerTech/traps/infeedStatusEvent-Error:%dpname%:%nodeid%:%interface%:%parm[#2]%i:%parm[#3]%" auto-clean="false"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>2</mevalue>
- </maskelement>
- <varbind>
- <vbnumber>4</vbnumber>
- <vbvalue>2</vbvalue>
- </varbind>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/infeedStatusEvent-Error</uei>
- <event-label>Sentry3-MIB defined trap event: infeedStatusEvent-Error</event-label>
- <descr>
- <p>Input feed status event. If enabled, this trap is sent when
- the infeedStatus indicates an error state ('offError',
- 'onError', or 'noComm'). This trap is repeated periodically
- while the infeedStatus remains in an error state. If the
- infeedStatus returns to a non-error state ('off' or 'on'),
- this trap is sent once more with the non-error infeedStatus,
- and then stops being repeated.
- While the infeedStatus indicates an error state, load
- traps are suppressed for the input feed, and, if the
- infeedCapabilities 'failSafe' bit is FALSE, all status and
- load traps are suppressed for outlets on the input feed.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- infeedID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- infeedName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- infeedStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- off(0)
- on(1)
- offWait(2)
- onWait(3)
- offError(4)
- onError(5)
- noComm(6)
- </p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: Input Feed Status offWait (error)
- systemLocation=%parm[#1]%
- infeedID=%parm[#2]%
- infeedName=%parm[#3]%
- </logmsg>
- <severity>Minor</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[#2]%:%parm[#3]%" alarm-type="1" auto-clean="false"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>2</mevalue>
- </maskelement>
- <varbind>
- <vbnumber>4</vbnumber>
- <vbvalue>3</vbvalue>
- </varbind>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/infeedStatusEvent-Error</uei>
- <event-label>Sentry3-MIB defined trap event: infeedStatusEvent-Error</event-label>
- <descr>
- <p>Input feed status event. If enabled, this trap is sent when
- the infeedStatus indicates an error state ('offError',
- 'onError', or 'noComm'). This trap is repeated periodically
- while the infeedStatus remains in an error state. If the
- infeedStatus returns to a non-error state ('off' or 'on'),
- this trap is sent once more with the non-error infeedStatus,
- and then stops being repeated.
- While the infeedStatus indicates an error state, load
- traps are suppressed for the input feed, and, if the
- infeedCapabilities 'failSafe' bit is FALSE, all status and
- load traps are suppressed for outlets on the input feed.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- infeedID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- infeedName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- infeedStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- off(0)
- on(1)
- offWait(2)
- onWait(3)
- offError(4)
- onError(5)
- noComm(6)
- </p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: Input Feed Status onWait (error)
- systemLocation=%parm[#1]%
- infeedID=%parm[#2]%
- infeedName=%parm[#3]%
- </logmsg>
- <severity>Minor</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[#2]%:%parm[#3]%" alarm-type="1" auto-clean="false"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>2</mevalue>
- </maskelement>
- <varbind>
- <vbnumber>4</vbnumber>
- <vbvalue>4</vbvalue>
- </varbind>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/infeedStatusEvent-Error</uei>
- <event-label>Sentry3-MIB defined trap event: infeedStatusEvent-Error</event-label>
- <descr>
- <p>Input feed status event. If enabled, this trap is sent when
- the infeedStatus indicates an error state ('offError',
- 'onError', or 'noComm'). This trap is repeated periodically
- while the infeedStatus remains in an error state. If the
- infeedStatus returns to a non-error state ('off' or 'on'),
- this trap is sent once more with the non-error infeedStatus,
- and then stops being repeated.
- While the infeedStatus indicates an error state, load
- traps are suppressed for the input feed, and, if the
- infeedCapabilities 'failSafe' bit is FALSE, all status and
- load traps are suppressed for outlets on the input feed.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- infeedID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- infeedName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- infeedStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- off(0)
- on(1)
- offWait(2)
- onWait(3)
- offError(4)
- onError(5)
- noComm(6)
- </p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: Input Feed Status offError (error)
- systemLocation=%parm[#1]%
- infeedID=%parm[#2]%
- infeedName=%parm[#3]%
- </logmsg>
- <severity>Minor</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[#2]%:%parm[#3]%" alarm-type="1" auto-clean="false"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>2</mevalue>
- </maskelement>
- <varbind>
- <vbnumber>4</vbnumber>
- <vbvalue>5</vbvalue>
- </varbind>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/infeedStatusEvent-Error</uei>
- <event-label>Sentry3-MIB defined trap event: infeedStatusEvent-Error</event-label>
- <descr>
- <p>Input feed status event. If enabled, this trap is sent when
- the infeedStatus indicates an error state ('offError',
- 'onError', or 'noComm'). This trap is repeated periodically
- while the infeedStatus remains in an error state. If the
- infeedStatus returns to a non-error state ('off' or 'on'),
- this trap is sent once more with the non-error infeedStatus,
- and then stops being repeated.
- While the infeedStatus indicates an error state, load
- traps are suppressed for the input feed, and, if the
- infeedCapabilities 'failSafe' bit is FALSE, all status and
- load traps are suppressed for outlets on the input feed.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- infeedID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- infeedName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- infeedStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- off(0)
- on(1)
- offWait(2)
- onWait(3)
- offError(4)
- onError(5)
- noComm(6)
- </p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: Input Feed Status onError (error)
- systemLocation=%parm[#1]%
- infeedID=%parm[#2]%
- infeedName=%parm[#3]%
- </logmsg>
- <severity>Minor</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[#2]%:%parm[#3]%" alarm-type="1" auto-clean="false"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>2</mevalue>
- </maskelement>
- <varbind>
- <vbnumber>4</vbnumber>
- <vbvalue>6</vbvalue>
- </varbind>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/infeedStatusEvent-Error</uei>
- <event-label>Sentry3-MIB defined trap event: infeedStatusEvent-Error</event-label>
- <descr>
- <p>Input feed status event. If enabled, this trap is sent when
- the infeedStatus indicates an error state ('offError',
- 'onError', or 'noComm'). This trap is repeated periodically
- while the infeedStatus remains in an error state. If the
- infeedStatus returns to a non-error state ('off' or 'on'),
- this trap is sent once more with the non-error infeedStatus,
- and then stops being repeated.
- While the infeedStatus indicates an error state, load
- traps are suppressed for the input feed, and, if the
- infeedCapabilities 'failSafe' bit is FALSE, all status and
- load traps are suppressed for outlets on the input feed.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- infeedID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- infeedName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- infeedStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- off(0)
- on(1)
- offWait(2)
- onWait(3)
- offError(4)
- onError(5)
- noComm(6)
- </p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: Input Feed Status noComm (error)
- systemLocation=%parm[#1]%
- infeedID=%parm[#2]%
- infeedName=%parm[#3]%
- </logmsg>
- <severity>Minor</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[#2]%:%parm[#3]%" alarm-type="1" auto-clean="false"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>2</mevalue>
- </maskelement>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/infeedStatusEvent</uei>
- <event-label>Sentry3-MIB defined trap event: infeedStatusEvent</event-label>
- <descr>
- <p>Input feed status event. If enabled, this trap is sent when
- the infeedStatus indicates an error state ('offError',
- 'onError', or 'noComm'). This trap is repeated periodically
- while the infeedStatus remains in an error state. If the
- infeedStatus returns to a non-error state ('off' or 'on'),
- this trap is sent once more with the non-error infeedStatus,
- and then stops being repeated.
- While the infeedStatus indicates an error state, load
- traps are suppressed for the input feed, and, if the
- infeedCapabilities 'failSafe' bit is FALSE, all status and
- load traps are suppressed for outlets on the input feed.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- infeedID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- infeedName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- infeedStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- off(0)
- on(1)
- offWait(2)
- onWait(3)
- offError(4)
- onError(5)
- noComm(6)
- </p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: infeedStatusEvent trap received
- systemLocation=%parm[#1]%
- infeedID=%parm[#2]%
- infeedName=%parm[#3]%
- </logmsg>
- <severity>Indeterminate</severity>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>3</mevalue>
- </maskelement>
- <varbind>
- <vbnumber>4</vbnumber>
- <vbvalue>0</vbvalue>
- </varbind>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/infeedLoadEvent-Normal</uei>
- <event-label>Sentry3-MIB defined trap event: infeedLoadEvent-Normal</event-label>
- <descr>
- <p>Input feed load event. If enabled, this trap is sent when
- the infeedLoadStatus indicates an error state ('loadLow',
- 'loadHigh', 'overLoad', 'readError', or 'noComm'). This
- trap is repeated periodically while the infeedLoadStatus
- remains in an error state. If the infeedLoadStatus returns
- to a non-error state ('normal' or 'notOn'), this trap is
- sent once more with the non-error infeedLoadStatus, and then
- stops being repeated.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- infeedID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- infeedName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- infeedLoadStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- normal(0)
- notOn(1)
- reading(2)
- loadLow(3)
- loadHigh(4)
- overLoad(5)
- readError(6)
- noComm(7)
- </p></td></tr>
- <tr><td><b>
- infeedLoadValue</b></td><td>
- %parm[#5]%;</td><td><p></p></td></tr>
- <tr><td><b>
- infeedLoadHighThresh</b></td><td>
- %parm[#6]%;</td><td><p></p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: infeedLoadEvent normal trap received
- systemLocation=%parm[#1]%
- infeedID=%parm[#2]%
- infeedName=%parm[#3]%
- infeedLoadStatus=%parm[#4]%
- infeedLoadValue=%parm[#5]%
- infeedLoadHighThresh=%parm[#6]%</p>
- </logmsg>
- <severity>Normal</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[#2]%:%parm[#3]%" alarm-type="2" clear-key="uei.opennms.org/vendor/ServerTech/traps/infeedLoadEvent-Error:%dpname%:%nodeid%:%interface%:%parm[#2]%i:%parm[#3]%" auto-clean="false"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>3</mevalue>
- </maskelement>
- <varbind>
- <vbnumber>4</vbnumber>
- <vbvalue>1</vbvalue>
- </varbind>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/infeedLoadEvent-Normal</uei>
- <event-label>Sentry3-MIB defined trap event: infeedLoadEvent-Normal</event-label>
- <descr>
- <p>Input feed load event. If enabled, this trap is sent when
- the infeedLoadStatus indicates an error state ('loadLow',
- 'loadHigh', 'overLoad', 'readError', or 'noComm'). This
- trap is repeated periodically while the infeedLoadStatus
- remains in an error state. If the infeedLoadStatus returns
- to a non-error state ('normal' or 'notOn'), this trap is
- sent once more with the non-error infeedLoadStatus, and then
- stops being repeated.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- infeedID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- infeedName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- infeedLoadStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- normal(0)
- notOn(1)
- reading(2)
- loadLow(3)
- loadHigh(4)
- overLoad(5)
- readError(6)
- noComm(7)
- </p></td></tr>
- <tr><td><b>
- infeedLoadValue</b></td><td>
- %parm[#5]%;</td><td><p></p></td></tr>
- <tr><td><b>
- infeedLoadHighThresh</b></td><td>
- %parm[#6]%;</td><td><p></p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: infeedLoadEvent notOn trap received
- systemLocation=%parm[#1]%
- infeedID=%parm[#2]%
- infeedName=%parm[#3]%
- infeedLoadStatus=%parm[#4]%
- infeedLoadValue=%parm[#5]%
- infeedLoadHighThresh=%parm[#6]%</p>
- </logmsg>
- <severity>Normal</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[#2]%:%parm[#3]%" alarm-type="2" clear-key="uei.opennms.org/vendor/ServerTech/traps/infeedLoadEvent-Error:%dpname%:%nodeid%:%interface%:%parm[#2]%i:%parm[#3]%" auto-clean="false"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>3</mevalue>
- </maskelement>
- <varbind>
- <vbnumber>4</vbnumber>
- <vbvalue>2</vbvalue>
- </varbind>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/infeedLoadEvent-Error</uei>
- <event-label>Sentry3-MIB defined trap event: infeedLoadEvent-Error</event-label>
- <descr>
- <p>Input feed load event. If enabled, this trap is sent when
- the infeedLoadStatus indicates an error state ('loadLow',
- 'loadHigh', 'overLoad', 'readError', or 'noComm'). This
- trap is repeated periodically while the infeedLoadStatus
- remains in an error state. If the infeedLoadStatus returns
- to a non-error state ('normal' or 'notOn'), this trap is
- sent once more with the non-error infeedLoadStatus, and then
- stops being repeated.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- infeedID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- infeedName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- infeedLoadStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- normal(0)
- notOn(1)
- reading(2)
- loadLow(3)
- loadHigh(4)
- overLoad(5)
- readError(6)
- noComm(7)
- </p></td></tr>
- <tr><td><b>
- infeedLoadValue</b></td><td>
- %parm[#5]%;</td><td><p></p></td></tr>
- <tr><td><b>
- infeedLoadHighThresh</b></td><td>
- %parm[#6]%;</td><td><p></p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: infeedLoadEvent reading trap received
- systemLocation=%parm[#1]%
- infeedID=%parm[#2]%
- infeedName=%parm[#3]%
- infeedLoadStatus=%parm[#4]%
- infeedLoadValue=%parm[#5]%
- infeedLoadHighThresh=%parm[#6]%</p>
- </logmsg>
- <severity>Warning</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[#2]%:%parm[#3]%" alarm-type="1" auto-clean="false"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>3</mevalue>
- </maskelement>
- <varbind>
- <vbnumber>4</vbnumber>
- <vbvalue>3</vbvalue>
- </varbind>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/infeedLoadEvent-Error</uei>
- <event-label>Sentry3-MIB defined trap event: infeedLoadEvent-Error</event-label>
- <descr>
- <p>Input feed load event. If enabled, this trap is sent when
- the infeedLoadStatus indicates an error state ('loadLow',
- 'loadHigh', 'overLoad', 'readError', or 'noComm'). This
- trap is repeated periodically while the infeedLoadStatus
- remains in an error state. If the infeedLoadStatus returns
- to a non-error state ('normal' or 'notOn'), this trap is
- sent once more with the non-error infeedLoadStatus, and then
- stops being repeated.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- infeedID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- infeedName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- infeedLoadStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- normal(0)
- notOn(1)
- reading(2)
- loadLow(3)
- loadHigh(4)
- overLoad(5)
- readError(6)
- noComm(7)
- </p></td></tr>
- <tr><td><b>
- infeedLoadValue</b></td><td>
- %parm[#5]%;</td><td><p></p></td></tr>
- <tr><td><b>
- infeedLoadHighThresh</b></td><td>
- %parm[#6]%;</td><td><p></p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: infeedLoadEvent low load trap received
- systemLocation=%parm[#1]%
- infeedID=%parm[#2]%
- infeedName=%parm[#3]%
- infeedLoadStatus=%parm[#4]%
- infeedLoadValue=%parm[#5]%
- infeedLoadHighThresh=%parm[#6]%</p>
- </logmsg>
- <severity>Minor</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[#2]%:%parm[#3]%" alarm-type="1" auto-clean="false"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>3</mevalue>
- </maskelement>
- <varbind>
- <vbnumber>4</vbnumber>
- <vbvalue>4</vbvalue>
- </varbind>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/infeedLoadEvent-Error</uei>
- <event-label>Sentry3-MIB defined trap event: infeedLoadEvent-Error</event-label>
- <descr>
- <p>Input feed load event. If enabled, this trap is sent when
- the infeedLoadStatus indicates an error state ('loadLow',
- 'loadHigh', 'overLoad', 'readError', or 'noComm'). This
- trap is repeated periodically while the infeedLoadStatus
- remains in an error state. If the infeedLoadStatus returns
- to a non-error state ('normal' or 'notOn'), this trap is
- sent once more with the non-error infeedLoadStatus, and then
- stops being repeated.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- infeedID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- infeedName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- infeedLoadStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- normal(0)
- notOn(1)
- reading(2)
- loadLow(3)
- loadHigh(4)
- overLoad(5)
- readError(6)
- noComm(7)
- </p></td></tr>
- <tr><td><b>
- infeedLoadValue</b></td><td>
- %parm[#5]%;</td><td><p></p></td></tr>
- <tr><td><b>
- infeedLoadHighThresh</b></td><td>
- %parm[#6]%;</td><td><p></p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: infeedLoadEvent high load trap received
- systemLocation=%parm[#1]%
- infeedID=%parm[#2]%
- infeedName=%parm[#3]%
- infeedLoadStatus=%parm[#4]%
- infeedLoadValue=%parm[#5]%
- infeedLoadHighThresh=%parm[#6]%</p>
- </logmsg>
- <severity>Minor</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[#2]%:%parm[#3]%" alarm-type="1" auto-clean="false"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>3</mevalue>
- </maskelement>
- <varbind>
- <vbnumber>4</vbnumber>
- <vbvalue>5</vbvalue>
- </varbind>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/infeedLoadEvent-Error</uei>
- <event-label>Sentry3-MIB defined trap event: infeedLoadEvent-Error</event-label>
- <descr>
- <p>Input feed load event. If enabled, this trap is sent when
- the infeedLoadStatus indicates an error state ('loadLow',
- 'loadHigh', 'overLoad', 'readError', or 'noComm'). This
- trap is repeated periodically while the infeedLoadStatus
- remains in an error state. If the infeedLoadStatus returns
- to a non-error state ('normal' or 'notOn'), this trap is
- sent once more with the non-error infeedLoadStatus, and then
- stops being repeated.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- infeedID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- infeedName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- infeedLoadStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- normal(0)
- notOn(1)
- reading(2)
- loadLow(3)
- loadHigh(4)
- overLoad(5)
- readError(6)
- noComm(7)
- </p></td></tr>
- <tr><td><b>
- infeedLoadValue</b></td><td>
- %parm[#5]%;</td><td><p></p></td></tr>
- <tr><td><b>
- infeedLoadHighThresh</b></td><td>
- %parm[#6]%;</td><td><p></p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: infeedLoadEvent over load trap received
- systemLocation=%parm[#1]%
- infeedID=%parm[#2]%
- infeedName=%parm[#3]%
- infeedLoadStatus=%parm[#4]%
- infeedLoadValue=%parm[#5]%
- infeedLoadHighThresh=%parm[#6]%</p>
- </logmsg>
- <severity>Minor</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[#2]%:%parm[#3]%" alarm-type="1" auto-clean="false"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>3</mevalue>
- </maskelement>
- <varbind>
- <vbnumber>4</vbnumber>
- <vbvalue>6</vbvalue>
- </varbind>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/infeedLoadEvent-Error</uei>
- <event-label>Sentry3-MIB defined trap event: infeedLoadEvent-Error</event-label>
- <descr>
- <p>Input feed load event. If enabled, this trap is sent when
- the infeedLoadStatus indicates an error state ('loadLow',
- 'loadHigh', 'overLoad', 'readError', or 'noComm'). This
- trap is repeated periodically while the infeedLoadStatus
- remains in an error state. If the infeedLoadStatus returns
- to a non-error state ('normal' or 'notOn'), this trap is
- sent once more with the non-error infeedLoadStatus, and then
- stops being repeated.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- infeedID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- infeedName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- infeedLoadStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- normal(0)
- notOn(1)
- reading(2)
- loadLow(3)
- loadHigh(4)
- overLoad(5)
- readError(6)
- noComm(7)
- </p></td></tr>
- <tr><td><b>
- infeedLoadValue</b></td><td>
- %parm[#5]%;</td><td><p></p></td></tr>
- <tr><td><b>
- infeedLoadHighThresh</b></td><td>
- %parm[#6]%;</td><td><p></p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: infeedLoadEvent read error trap received
- systemLocation=%parm[#1]%
- infeedID=%parm[#2]%
- infeedName=%parm[#3]%
- infeedLoadStatus=%parm[#4]%
- infeedLoadValue=%parm[#5]%
- infeedLoadHighThresh=%parm[#6]%</p>
- </logmsg>
- <severity>Minor</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[#2]%:%parm[#3]%" alarm-type="1" auto-clean="false"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>3</mevalue>
- </maskelement>
- <varbind>
- <vbnumber>4</vbnumber>
- <vbvalue>7</vbvalue>
- </varbind>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/infeedLoadEvent-Error</uei>
- <event-label>Sentry3-MIB defined trap event: infeedLoadEvent-Error</event-label>
- <descr>
- <p>Input feed load event. If enabled, this trap is sent when
- the infeedLoadStatus indicates an error state ('loadLow',
- 'loadHigh', 'overLoad', 'readError', or 'noComm'). This
- trap is repeated periodically while the infeedLoadStatus
- remains in an error state. If the infeedLoadStatus returns
- to a non-error state ('normal' or 'notOn'), this trap is
- sent once more with the non-error infeedLoadStatus, and then
- stops being repeated.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- infeedID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- infeedName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- infeedLoadStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- normal(0)
- notOn(1)
- reading(2)
- loadLow(3)
- loadHigh(4)
- overLoad(5)
- readError(6)
- noComm(7)
- </p></td></tr>
- <tr><td><b>
- infeedLoadValue</b></td><td>
- %parm[#5]%;</td><td><p></p></td></tr>
- <tr><td><b>
- infeedLoadHighThresh</b></td><td>
- %parm[#6]%;</td><td><p></p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: infeedLoadEvent noComm trap received
- systemLocation=%parm[#1]%
- infeedID=%parm[#2]%
- infeedName=%parm[#3]%
- infeedLoadStatus=%parm[#4]%
- infeedLoadValue=%parm[#5]%
- infeedLoadHighThresh=%parm[#6]%</p>
- </logmsg>
- <severity>Minor</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[#2]%:%parm[#3]%" alarm-type="1" auto-clean="false"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>3</mevalue>
- </maskelement>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/infeedLoadEvent</uei>
- <event-label>Sentry3-MIB defined trap event: infeedLoadEvent</event-label>
- <descr>
- <p>Input feed load event. If enabled, this trap is sent when
- the infeedLoadStatus indicates an error state ('loadLow',
- 'loadHigh', 'overLoad', 'readError', or 'noComm'). This
- trap is repeated periodically while the infeedLoadStatus
- remains in an error state. If the infeedLoadStatus returns
- to a non-error state ('normal' or 'notOn'), this trap is
- sent once more with the non-error infeedLoadStatus, and then
- stops being repeated.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- infeedID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- infeedName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- infeedLoadStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- normal(0)
- notOn(1)
- reading(2)
- loadLow(3)
- loadHigh(4)
- overLoad(5)
- readError(6)
- noComm(7)
- </p></td></tr>
- <tr><td><b>
- infeedLoadValue</b></td><td>
- %parm[#5]%;</td><td><p></p></td></tr>
- <tr><td><b>
- infeedLoadHighThresh</b></td><td>
- %parm[#6]%;</td><td><p></p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: infeedLoadEvent trap received
- systemLocation=%parm[#1]%
- infeedID=%parm[#2]%
- infeedName=%parm[#3]%
- infeedLoadStatus=%parm[#4]%
- infeedLoadValue=%parm[#5]%
- infeedLoadHighThresh=%parm[#6]%</p>
- </logmsg>
- <severity>Indeterminate</severity>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>4</mevalue>
- </maskelement>
- <varbind>
- <vbnumber>4</vbnumber>
- <vbvalue>0</vbvalue>
- </varbind>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/outletStatusEvent-Normal</uei>
- <event-label>Sentry3-MIB defined trap event: outletStatusEvent-Normal</event-label>
- <descr>
- <p>Outlet status event. If enabled, this trap is sent when the
- outletStatus indicates an error state ('offError', 'onError',
- 'noComm', 'offFuse', or 'onFuse'). This trap is repeated
- periodically while the outletStatus remains in an error state.
- If the outletStatus returns to a non-error state ('off' or
- 'on'), this trap is sent once more with the non-error
- outletStatus, and then stops being repeated.
- While the outletStatus indicates an error state, load traps
- are suppressed for the outlet.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- off(0)
- on(1)
- offWait(2)
- onWait(3)
- offError(4)
- onError(5)
- noComm(6)
- reading(7)
- offFuse(8)
- onFuse(9)
- </p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: outletStatusEvent off trap received
- systemLocation=%parm[#1]%
- outletID=%parm[#2]%
- outletName=%parm[#3]%
- outletStatus=%parm[#4]%</p>
- </logmsg>
- <severity>Normal</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[#2]%:%parm[#3]%" alarm-type="2" clear-key="uei.opennms.org/vendor/ServerTech/traps/outletStatusEvent-Error:%dpname%:%nodeid%:%interface%:%parm[#2]%i:%parm[#3]%" auto-clean="false"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>4</mevalue>
- </maskelement>
- <varbind>
- <vbnumber>4</vbnumber>
- <vbvalue>1</vbvalue>
- </varbind>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/outletStatusEvent-Normal</uei>
- <event-label>Sentry3-MIB defined trap event: outletStatusEvent-Normal</event-label>
- <descr>
- <p>Outlet status event. If enabled, this trap is sent when the
- outletStatus indicates an error state ('offError', 'onError',
- 'noComm', 'offFuse', or 'onFuse'). This trap is repeated
- periodically while the outletStatus remains in an error state.
- If the outletStatus returns to a non-error state ('off' or
- 'on'), this trap is sent once more with the non-error
- outletStatus, and then stops being repeated.
- While the outletStatus indicates an error state, load traps
- are suppressed for the outlet.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- off(0)
- on(1)
- offWait(2)
- onWait(3)
- offError(4)
- onError(5)
- noComm(6)
- reading(7)
- offFuse(8)
- onFuse(9)
- </p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: outletStatusEvent on trap received
- systemLocation=%parm[#1]%
- outletID=%parm[#2]%
- outletName=%parm[#3]%
- outletStatus=%parm[#4]%</p>
- </logmsg>
- <severity>Normal</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[#2]%:%parm[#3]%" alarm-type="2" clear-key="uei.opennms.org/vendor/ServerTech/traps/outletStatusEvent-Error:%dpname%:%nodeid%:%interface%:%parm[#2]%i:%parm[#3]%" auto-clean="false"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>4</mevalue>
- </maskelement>
- <varbind>
- <vbnumber>4</vbnumber>
- <vbvalue>2</vbvalue>
- </varbind>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/outletStatusEvent-Error</uei>
- <event-label>Sentry3-MIB defined trap event: outletStatusEvent-Error</event-label>
- <descr>
- <p>Outlet status event. If enabled, this trap is sent when the
- outletStatus indicates an error state ('offError', 'onError',
- 'noComm', 'offFuse', or 'onFuse'). This trap is repeated
- periodically while the outletStatus remains in an error state.
- If the outletStatus returns to a non-error state ('off' or
- 'on'), this trap is sent once more with the non-error
- outletStatus, and then stops being repeated.
- While the outletStatus indicates an error state, load traps
- are suppressed for the outlet.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- off(0)
- on(1)
- offWait(2)
- onWait(3)
- offError(4)
- onError(5)
- noComm(6)
- reading(7)
- offFuse(8)
- onFuse(9)
- </p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: outletStatusEvent offWait trap received
- systemLocation=%parm[#1]%
- outletID=%parm[#2]%
- outletName=%parm[#3]%
- outletStatus=%parm[#4]%</p>
- </logmsg>
- <severity>Minor</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[#2]%:%parm[#3]%" alarm-type="2" auto-clean="false"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>4</mevalue>
- </maskelement>
- <varbind>
- <vbnumber>4</vbnumber>
- <vbvalue>3</vbvalue>
- </varbind>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/outletStatusEvent-Error</uei>
- <event-label>Sentry3-MIB defined trap event: outletStatusEvent-Error</event-label>
- <descr>
- <p>Outlet status event. If enabled, this trap is sent when the
- outletStatus indicates an error state ('offError', 'onError',
- 'noComm', 'offFuse', or 'onFuse'). This trap is repeated
- periodically while the outletStatus remains in an error state.
- If the outletStatus returns to a non-error state ('off' or
- 'on'), this trap is sent once more with the non-error
- outletStatus, and then stops being repeated.
- While the outletStatus indicates an error state, load traps
- are suppressed for the outlet.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- off(0)
- on(1)
- offWait(2)
- onWait(3)
- offError(4)
- onError(5)
- noComm(6)
- reading(7)
- offFuse(8)
- onFuse(9)
- </p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: outletStatusEvent onWait trap received
- systemLocation=%parm[#1]%
- outletID=%parm[#2]%
- outletName=%parm[#3]%
- outletStatus=%parm[#4]%</p>
- </logmsg>
- <severity>Minor</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[#2]%:%parm[#3]%" alarm-type="2" auto-clean="false"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>4</mevalue>
- </maskelement>
- <varbind>
- <vbnumber>4</vbnumber>
- <vbvalue>4</vbvalue>
- </varbind>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/outletStatusEvent-Error</uei>
- <event-label>Sentry3-MIB defined trap event: outletStatusEvent-Error</event-label>
- <descr>
- <p>Outlet status event. If enabled, this trap is sent when the
- outletStatus indicates an error state ('offError', 'onError',
- 'noComm', 'offFuse', or 'onFuse'). This trap is repeated
- periodically while the outletStatus remains in an error state.
- If the outletStatus returns to a non-error state ('off' or
- 'on'), this trap is sent once more with the non-error
- outletStatus, and then stops being repeated.
- While the outletStatus indicates an error state, load traps
- are suppressed for the outlet.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- off(0)
- on(1)
- offWait(2)
- onWait(3)
- offError(4)
- onError(5)
- noComm(6)
- reading(7)
- offFuse(8)
- onFuse(9)
- </p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: outletStatusEvent offError trap received
- systemLocation=%parm[#1]%
- outletID=%parm[#2]%
- outletName=%parm[#3]%
- outletStatus=%parm[#4]%</p>
- </logmsg>
- <severity>Minor</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[#2]%:%parm[#3]%" alarm-type="2" auto-clean="false"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>4</mevalue>
- </maskelement>
- <varbind>
- <vbnumber>4</vbnumber>
- <vbvalue>5</vbvalue>
- </varbind>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/outletStatusEvent-Error</uei>
- <event-label>Sentry3-MIB defined trap event: outletStatusEvent-Error</event-label>
- <descr>
- <p>Outlet status event. If enabled, this trap is sent when the
- outletStatus indicates an error state ('offError', 'onError',
- 'noComm', 'offFuse', or 'onFuse'). This trap is repeated
- periodically while the outletStatus remains in an error state.
- If the outletStatus returns to a non-error state ('off' or
- 'on'), this trap is sent once more with the non-error
- outletStatus, and then stops being repeated.
- While the outletStatus indicates an error state, load traps
- are suppressed for the outlet.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- off(0)
- on(1)
- offWait(2)
- onWait(3)
- offError(4)
- onError(5)
- noComm(6)
- reading(7)
- offFuse(8)
- onFuse(9)
- </p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: outletStatusEvent onError trap received
- systemLocation=%parm[#1]%
- outletID=%parm[#2]%
- outletName=%parm[#3]%
- outletStatus=%parm[#4]%</p>
- </logmsg>
- <severity>Minor</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[#2]%:%parm[#3]%" alarm-type="2" auto-clean="false"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>4</mevalue>
- </maskelement>
- <varbind>
- <vbnumber>4</vbnumber>
- <vbvalue>6</vbvalue>
- </varbind>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/outletStatusEvent-Error</uei>
- <event-label>Sentry3-MIB defined trap event: outletStatusEvent-Error</event-label>
- <descr>
- <p>Outlet status event. If enabled, this trap is sent when the
- outletStatus indicates an error state ('offError', 'onError',
- 'noComm', 'offFuse', or 'onFuse'). This trap is repeated
- periodically while the outletStatus remains in an error state.
- If the outletStatus returns to a non-error state ('off' or
- 'on'), this trap is sent once more with the non-error
- outletStatus, and then stops being repeated.
- While the outletStatus indicates an error state, load traps
- are suppressed for the outlet.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- off(0)
- on(1)
- offWait(2)
- onWait(3)
- offError(4)
- onError(5)
- noComm(6)
- reading(7)
- offFuse(8)
- onFuse(9)
- </p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: outletStatusEvent noComm trap received
- systemLocation=%parm[#1]%
- outletID=%parm[#2]%
- outletName=%parm[#3]%
- outletStatus=%parm[#4]%</p>
- </logmsg>
- <severity>Minor</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[#2]%:%parm[#3]%" alarm-type="2" auto-clean="false"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>4</mevalue>
- </maskelement>
- <varbind>
- <vbnumber>4</vbnumber>
- <vbvalue>7</vbvalue>
- </varbind>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/outletStatusEvent-Error</uei>
- <event-label>Sentry3-MIB defined trap event: outletStatusEvent-Error</event-label>
- <descr>
- <p>Outlet status event. If enabled, this trap is sent when the
- outletStatus indicates an error state ('offError', 'onError',
- 'noComm', 'offFuse', or 'onFuse'). This trap is repeated
- periodically while the outletStatus remains in an error state.
- If the outletStatus returns to a non-error state ('off' or
- 'on'), this trap is sent once more with the non-error
- outletStatus, and then stops being repeated.
- While the outletStatus indicates an error state, load traps
- are suppressed for the outlet.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- off(0)
- on(1)
- offWait(2)
- onWait(3)
- offError(4)
- onError(5)
- noComm(6)
- reading(7)
- offFuse(8)
- onFuse(9)
- </p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: outletStatusEvent reading trap received
- systemLocation=%parm[#1]%
- outletID=%parm[#2]%
- outletName=%parm[#3]%
- outletStatus=%parm[#4]%</p>
- </logmsg>
- <severity>Minor</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[#2]%:%parm[#3]%" alarm-type="2" auto-clean="false"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>4</mevalue>
- </maskelement>
- <varbind>
- <vbnumber>4</vbnumber>
- <vbvalue>8</vbvalue>
- </varbind>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/outletStatusEvent-Error</uei>
- <event-label>Sentry3-MIB defined trap event: outletStatusEvent-Error</event-label>
- <descr>
- <p>Outlet status event. If enabled, this trap is sent when the
- outletStatus indicates an error state ('offError', 'onError',
- 'noComm', 'offFuse', or 'onFuse'). This trap is repeated
- periodically while the outletStatus remains in an error state.
- If the outletStatus returns to a non-error state ('off' or
- 'on'), this trap is sent once more with the non-error
- outletStatus, and then stops being repeated.
- While the outletStatus indicates an error state, load traps
- are suppressed for the outlet.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- off(0)
- on(1)
- offWait(2)
- onWait(3)
- offError(4)
- onError(5)
- noComm(6)
- reading(7)
- offFuse(8)
- onFuse(9)
- </p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: outletStatusEvent offFuse trap received
- systemLocation=%parm[#1]%
- outletID=%parm[#2]%
- outletName=%parm[#3]%
- outletStatus=%parm[#4]%</p>
- </logmsg>
- <severity>Minor</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[#2]%:%parm[#3]%" alarm-type="2" auto-clean="false"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>4</mevalue>
- </maskelement>
- <varbind>
- <vbnumber>4</vbnumber>
- <vbvalue>9</vbvalue>
- </varbind>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/outletStatusEvent-Error</uei>
- <event-label>Sentry3-MIB defined trap event: outletStatusEvent-Error</event-label>
- <descr>
- <p>Outlet status event. If enabled, this trap is sent when the
- outletStatus indicates an error state ('offError', 'onError',
- 'noComm', 'offFuse', or 'onFuse'). This trap is repeated
- periodically while the outletStatus remains in an error state.
- If the outletStatus returns to a non-error state ('off' or
- 'on'), this trap is sent once more with the non-error
- outletStatus, and then stops being repeated.
- While the outletStatus indicates an error state, load traps
- are suppressed for the outlet.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- off(0)
- on(1)
- offWait(2)
- onWait(3)
- offError(4)
- onError(5)
- noComm(6)
- reading(7)
- offFuse(8)
- onFuse(9)
- </p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: outletStatusEvent onFuse trap received
- systemLocation=%parm[#1]%
- outletID=%parm[#2]%
- outletName=%parm[#3]%
- outletStatus=%parm[#4]%</p>
- </logmsg>
- <severity>Minor</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[#2]%:%parm[#3]%" alarm-type="2" auto-clean="false"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>4</mevalue>
- </maskelement>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/outletStatusEvent</uei>
- <event-label>Sentry3-MIB defined trap event: outletStatusEvent</event-label>
- <descr>
- <p>Outlet status event. If enabled, this trap is sent when the
- outletStatus indicates an error state ('offError', 'onError',
- 'noComm', 'offFuse', or 'onFuse'). This trap is repeated
- periodically while the outletStatus remains in an error state.
- If the outletStatus returns to a non-error state ('off' or
- 'on'), this trap is sent once more with the non-error
- outletStatus, and then stops being repeated.
- While the outletStatus indicates an error state, load traps
- are suppressed for the outlet.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- off(0)
- on(1)
- offWait(2)
- onWait(3)
- offError(4)
- onError(5)
- noComm(6)
- reading(7)
- offFuse(8)
- onFuse(9)
- </p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: outletStatusEvent trap received
- systemLocation=%parm[#1]%
- outletID=%parm[#2]%
- outletName=%parm[#3]%
- outletStatus=%parm[#4]%</p>
- </logmsg>
- <severity>Indeterminate</severity>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>5</mevalue>
- </maskelement>
- <varbind>
- <vbnumber>4</vbnumber>
- <vbvalue>0</vbvalue>
- </varbind>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/outletLoadEvent-Normal</uei>
- <event-label>Sentry3-MIB defined trap event: outletLoadEvent-Normal</event-label>
- <descr>
- <p>Outlet load event. If enabled, this trap is sent when the
- outletLoadStatus indicates an error state ('loadLow',
- 'loadHigh', 'overLoad', 'readError', or 'noComm'). This
- trap is repeated periodically while the outletLoadStatus
- remains in an error state. If the outletLoadStatus returns
- to a non-error state ('normal' or 'notOn'), this trap is
- sent once more with the non-error outletLoadStatus, and then
- stops being repeated.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletLoadStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- normal(0)
- notOn(1)
- reading(2)
- loadLow(3)
- loadHigh(4)
- overLoad(5)
- readError(6)
- noComm(7)
- </p></td></tr>
- <tr><td><b>
- outletLoadValue</b></td><td>
- %parm[#5]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletLoadLowThresh</b></td><td>
- %parm[#6]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletLoadHighThresh</b></td><td>
- %parm[#7]%;</td><td><p></p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: outletLoadEvent normal trap received
- systemLocation=%parm[#1]%
- outletID=%parm[#2]%
- outletName=%parm[#3]%
- </logmsg>
- <severity>Normal</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[#2]%:%parm[#3]%" alarm-type="2" clear-key="uei.opennms.org/vendor/ServerTech/traps/outletLoadEvent-Error:%dpname%:%nodeid%:%interface%:%parm[#2]%i:%parm[#3]%" auto-clean="false"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>5</mevalue>
- </maskelement>
- <varbind>
- <vbnumber>4</vbnumber>
- <vbvalue>1</vbvalue>
- </varbind>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/outletLoadEvent-Normal</uei>
- <event-label>Sentry3-MIB defined trap event: outletLoadEvent-Normal</event-label>
- <descr>
- <p>Outlet load event. If enabled, this trap is sent when the
- outletLoadStatus indicates an error state ('loadLow',
- 'loadHigh', 'overLoad', 'readError', or 'noComm'). This
- trap is repeated periodically while the outletLoadStatus
- remains in an error state. If the outletLoadStatus returns
- to a non-error state ('normal' or 'notOn'), this trap is
- sent once more with the non-error outletLoadStatus, and then
- stops being repeated.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletLoadStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- normal(0)
- notOn(1)
- reading(2)
- loadLow(3)
- loadHigh(4)
- overLoad(5)
- readError(6)
- noComm(7)
- </p></td></tr>
- <tr><td><b>
- outletLoadValue</b></td><td>
- %parm[#5]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletLoadLowThresh</b></td><td>
- %parm[#6]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletLoadHighThresh</b></td><td>
- %parm[#7]%;</td><td><p></p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: outletLoadEvent notOn trap received
- systemLocation=%parm[#1]%
- outletID=%parm[#2]%
- outletName=%parm[#3]%
- </logmsg>
- <severity>Normal</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[#2]%:%parm[#3]%" alarm-type="2" clear-key="uei.opennms.org/vendor/ServerTech/traps/outletLoadEvent-Error:%dpname%:%nodeid%:%interface%:%parm[#2]%i:%parm[#3]%" auto-clean="false"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>5</mevalue>
- </maskelement>
- <varbind>
- <vbnumber>4</vbnumber>
- <vbvalue>2</vbvalue>
- </varbind>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/outletLoadEvent-Error</uei>
- <event-label>Sentry3-MIB defined trap event: outletLoadEvent-Error</event-label>
- <descr>
- <p>Outlet load event. If enabled, this trap is sent when the
- outletLoadStatus indicates an error state ('loadLow',
- 'loadHigh', 'overLoad', 'readError', or 'noComm'). This
- trap is repeated periodically while the outletLoadStatus
- remains in an error state. If the outletLoadStatus returns
- to a non-error state ('normal' or 'notOn'), this trap is
- sent once more with the non-error outletLoadStatus, and then
- stops being repeated.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletLoadStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- normal(0)
- notOn(1)
- reading(2)
- loadLow(3)
- loadHigh(4)
- overLoad(5)
- readError(6)
- noComm(7)
- </p></td></tr>
- <tr><td><b>
- outletLoadValue</b></td><td>
- %parm[#5]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletLoadLowThresh</b></td><td>
- %parm[#6]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletLoadHighThresh</b></td><td>
- %parm[#7]%;</td><td><p></p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: outletLoadEvent reading trap received
- systemLocation=%parm[#1]%
- outletID=%parm[#2]%
- outletName=%parm[#3]%
- </logmsg>
- <severity>Minor</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[#2]%:%parm[#3]%" alarm-type="2" auto-clean="false"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>5</mevalue>
- </maskelement>
- <varbind>
- <vbnumber>4</vbnumber>
- <vbvalue>3</vbvalue>
- </varbind>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/outletLoadEvent-Error</uei>
- <event-label>Sentry3-MIB defined trap event: outletLoadEvent-Error</event-label>
- <descr>
- <p>Outlet load event. If enabled, this trap is sent when the
- outletLoadStatus indicates an error state ('loadLow',
- 'loadHigh', 'overLoad', 'readError', or 'noComm'). This
- trap is repeated periodically while the outletLoadStatus
- remains in an error state. If the outletLoadStatus returns
- to a non-error state ('normal' or 'notOn'), this trap is
- sent once more with the non-error outletLoadStatus, and then
- stops being repeated.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletLoadStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- normal(0)
- notOn(1)
- reading(2)
- loadLow(3)
- loadHigh(4)
- overLoad(5)
- readError(6)
- noComm(7)
- </p></td></tr>
- <tr><td><b>
- outletLoadValue</b></td><td>
- %parm[#5]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletLoadLowThresh</b></td><td>
- %parm[#6]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletLoadHighThresh</b></td><td>
- %parm[#7]%;</td><td><p></p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: outletLoadEvent low load trap received
- systemLocation=%parm[#1]%
- outletID=%parm[#2]%
- outletName=%parm[#3]%
- </logmsg>
- <severity>Minor</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[#2]%:%parm[#3]%" alarm-type="2" auto-clean="false"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>5</mevalue>
- </maskelement>
- <varbind>
- <vbnumber>4</vbnumber>
- <vbvalue>4</vbvalue>
- </varbind>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/outletLoadEvent-Error</uei>
- <event-label>Sentry3-MIB defined trap event: outletLoadEvent-Error</event-label>
- <descr>
- <p>Outlet load event. If enabled, this trap is sent when the
- outletLoadStatus indicates an error state ('loadLow',
- 'loadHigh', 'overLoad', 'readError', or 'noComm'). This
- trap is repeated periodically while the outletLoadStatus
- remains in an error state. If the outletLoadStatus returns
- to a non-error state ('normal' or 'notOn'), this trap is
- sent once more with the non-error outletLoadStatus, and then
- stops being repeated.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletLoadStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- normal(0)
- notOn(1)
- reading(2)
- loadLow(3)
- loadHigh(4)
- overLoad(5)
- readError(6)
- noComm(7)
- </p></td></tr>
- <tr><td><b>
- outletLoadValue</b></td><td>
- %parm[#5]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletLoadLowThresh</b></td><td>
- %parm[#6]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletLoadHighThresh</b></td><td>
- %parm[#7]%;</td><td><p></p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: outletLoadEvent high load trap received
- systemLocation=%parm[#1]%
- outletID=%parm[#2]%
- outletName=%parm[#3]%
- </logmsg>
- <severity>Minor</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[#2]%:%parm[#3]%" alarm-type="2" auto-clean="false"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>5</mevalue>
- </maskelement>
- <varbind>
- <vbnumber>4</vbnumber>
- <vbvalue>5</vbvalue>
- </varbind>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/outletLoadEvent-Error</uei>
- <event-label>Sentry3-MIB defined trap event: outletLoadEvent-Error</event-label>
- <descr>
- <p>Outlet load event. If enabled, this trap is sent when the
- outletLoadStatus indicates an error state ('loadLow',
- 'loadHigh', 'overLoad', 'readError', or 'noComm'). This
- trap is repeated periodically while the outletLoadStatus
- remains in an error state. If the outletLoadStatus returns
- to a non-error state ('normal' or 'notOn'), this trap is
- sent once more with the non-error outletLoadStatus, and then
- stops being repeated.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletLoadStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- normal(0)
- notOn(1)
- reading(2)
- loadLow(3)
- loadHigh(4)
- overLoad(5)
- readError(6)
- noComm(7)
- </p></td></tr>
- <tr><td><b>
- outletLoadValue</b></td><td>
- %parm[#5]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletLoadLowThresh</b></td><td>
- %parm[#6]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletLoadHighThresh</b></td><td>
- %parm[#7]%;</td><td><p></p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: outletLoadEvent over load trap received
- systemLocation=%parm[#1]%
- outletID=%parm[#2]%
- outletName=%parm[#3]%
- </logmsg>
- <severity>Minor</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[#2]%:%parm[#3]%" alarm-type="2" auto-clean="false"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>5</mevalue>
- </maskelement>
- <varbind>
- <vbnumber>4</vbnumber>
- <vbvalue>6</vbvalue>
- </varbind>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/outletLoadEvent-Error</uei>
- <event-label>Sentry3-MIB defined trap event: outletLoadEvent-Error</event-label>
- <descr>
- <p>Outlet load event. If enabled, this trap is sent when the
- outletLoadStatus indicates an error state ('loadLow',
- 'loadHigh', 'overLoad', 'readError', or 'noComm'). This
- trap is repeated periodically while the outletLoadStatus
- remains in an error state. If the outletLoadStatus returns
- to a non-error state ('normal' or 'notOn'), this trap is
- sent once more with the non-error outletLoadStatus, and then
- stops being repeated.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletLoadStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- normal(0)
- notOn(1)
- reading(2)
- loadLow(3)
- loadHigh(4)
- overLoad(5)
- readError(6)
- noComm(7)
- </p></td></tr>
- <tr><td><b>
- outletLoadValue</b></td><td>
- %parm[#5]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletLoadLowThresh</b></td><td>
- %parm[#6]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletLoadHighThresh</b></td><td>
- %parm[#7]%;</td><td><p></p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: outletLoadEvent read error trap received
- systemLocation=%parm[#1]%
- outletID=%parm[#2]%
- outletName=%parm[#3]%
- </logmsg>
- <severity>Minor</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[#2]%:%parm[#3]%" alarm-type="2" auto-clean="false"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>5</mevalue>
- </maskelement>
- <varbind>
- <vbnumber>4</vbnumber>
- <vbvalue>7</vbvalue>
- </varbind>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/outletLoadEvent-Error</uei>
- <event-label>Sentry3-MIB defined trap event: outletLoadEvent-Error</event-label>
- <descr>
- <p>Outlet load event. If enabled, this trap is sent when the
- outletLoadStatus indicates an error state ('loadLow',
- 'loadHigh', 'overLoad', 'readError', or 'noComm'). This
- trap is repeated periodically while the outletLoadStatus
- remains in an error state. If the outletLoadStatus returns
- to a non-error state ('normal' or 'notOn'), this trap is
- sent once more with the non-error outletLoadStatus, and then
- stops being repeated.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletLoadStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- normal(0)
- notOn(1)
- reading(2)
- loadLow(3)
- loadHigh(4)
- overLoad(5)
- readError(6)
- noComm(7)
- </p></td></tr>
- <tr><td><b>
- outletLoadValue</b></td><td>
- %parm[#5]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletLoadLowThresh</b></td><td>
- %parm[#6]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletLoadHighThresh</b></td><td>
- %parm[#7]%;</td><td><p></p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: outletLoadEvent noComm trap received
- systemLocation=%parm[#1]%
- outletID=%parm[#2]%
- outletName=%parm[#3]%
- </logmsg>
- <severity>Minor</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[#2]%:%parm[#3]%" alarm-type="2" auto-clean="false"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>5</mevalue>
- </maskelement>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/outletLoadEvent</uei>
- <event-label>Sentry3-MIB defined trap event: outletLoadEvent</event-label>
- <descr>
- <p>Outlet load event. If enabled, this trap is sent when the
- outletLoadStatus indicates an error state ('loadLow',
- 'loadHigh', 'overLoad', 'readError', or 'noComm'). This
- trap is repeated periodically while the outletLoadStatus
- remains in an error state. If the outletLoadStatus returns
- to a non-error state ('normal' or 'notOn'), this trap is
- sent once more with the non-error outletLoadStatus, and then
- stops being repeated.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletLoadStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- normal(0)
- notOn(1)
- reading(2)
- loadLow(3)
- loadHigh(4)
- overLoad(5)
- readError(6)
- noComm(7)
- </p></td></tr>
- <tr><td><b>
- outletLoadValue</b></td><td>
- %parm[#5]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletLoadLowThresh</b></td><td>
- %parm[#6]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletLoadHighThresh</b></td><td>
- %parm[#7]%;</td><td><p></p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: outletLoadEvent trap received
- systemLocation=%parm[#1]%
- outletID=%parm[#2]%
- outletName=%parm[#3]%
- outletLoadStatus=%parm[#4]%
- outletLoadValue=%parm[#5]%
- outletLoadLowThresh=%parm[#6]%
- outletLoadHighThresh=%parm[#7]%</p>
- </logmsg>
- <severity>Indeterminate</severity>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>6</mevalue>
- </maskelement>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/outletChangeEvent</uei>
- <event-label>Sentry3-MIB defined trap event: outletChangeEvent</event-label>
- <descr>
- <p>Outlet on/off change event. If enabled, this trap is sent
- when the outletStatus changes from any 'on' state ('on',
- 'onWait', 'onError', or 'onFuse') to any 'off' state ('off',
- 'offWait', 'offError', or 'offFuse'), and vice-versa.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- outletStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- off(0)
- on(1)
- offWait(2)
- onWait(3)
- offError(4)
- onError(5)
- noComm(6)
- reading(7)
- offFuse(8)
- onFuse(9)
- </p></td></tr>
- <tr><td><b>
- outletControlState</b></td><td>
- %parm[#5]%;</td><td><p>
- idleOff(0)
- idleOn(1)
- wakeOff(2)
- wakeOn(3)
- off(4)
- on(5)
- lockedOff(6)
- lockedOn(7)
- reboot(8)
- shutdown(9)
- pendOn(10)
- pendOff(11)
- minimumOff(12)
- minimumOn(13)
- eventOff(14)
- eventOn(15)
- eventReboot(16)
- eventShutdown(17)
- </p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: outletChangeEvent trap received
- outletID=%parm[#2]%
- outletName=%parm[#3]%
- </logmsg>
- <severity>Indeterminate</severity>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>7</mevalue>
- </maskelement>
- <varbind>
- <vbnumber>4</vbnumber>
- <vbvalue>0</vbvalue>
- </varbind>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/envMonStatusEvent-Normal</uei>
- <event-label>Sentry3-MIB defined trap event: envMonStatusEvent-Normal</event-label>
- <descr>
- <p>Environmental monitor status event. If enabled, this trap
- is sent when the envMonStatus indicates an error state
- ('noComm'). This trap is repeated periodically while the
- envMonStatus remains in an error state. If the envMonStatus
- returns to a non-error state ('normal'), this trap is sent
- once more with the non-error envMonStatus, and then stops
- being repeated.
- While the envMonStatus indicates an error state, all status
- traps are suppressed for the water sensor, ADC, temperature/
- humudity sensors, and contact closures on the environmental
- monitor.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- envMonID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- envMonName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- envMonStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- normal(0)
- noComm(1)
- </p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: envMonStatusEvent normal trap received
- systemLocation=%parm[#1]%
- envMonID=%parm[#2]%
- envMonName=%parm[#3]%
- </logmsg>
- <severity>Normal</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[#2]%:%parm[#3]%" alarm-type="2" clear-key="uei.opennms.org/vendor/ServerTech/traps/envMonStatusEvent-Error:%dpname%:%nodeid%:%interface%:%parm[#2]%i:%parm[#3]%" auto-clean="false"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>7</mevalue>
- </maskelement>
- <varbind>
- <vbnumber>4</vbnumber>
- <vbvalue>1</vbvalue>
- </varbind>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/envMonStatusEvent-Error</uei>
- <event-label>Sentry3-MIB defined trap event: envMonStatusEvent-Error</event-label>
- <descr>
- <p>Environmental monitor status event. If enabled, this trap
- is sent when the envMonStatus indicates an error state
- ('noComm'). This trap is repeated periodically while the
- envMonStatus remains in an error state. If the envMonStatus
- returns to a non-error state ('normal'), this trap is sent
- once more with the non-error envMonStatus, and then stops
- being repeated.
- While the envMonStatus indicates an error state, all status
- traps are suppressed for the water sensor, ADC, temperature/
- humudity sensors, and contact closures on the environmental
- monitor.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- envMonID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- envMonName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- envMonStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- normal(0)
- noComm(1)
- </p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: envMonStatusEvent noComm trap received
- systemLocation=%parm[#1]%
- envMonID=%parm[#2]%
- envMonName=%parm[#3]%
- </logmsg>
- <severity>Minor</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[#2]%:%parm[#3]%" alarm-type="1" auto-clean="false"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>7</mevalue>
- </maskelement>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/envMonStatusEvent</uei>
- <event-label>Sentry3-MIB defined trap event: envMonStatusEvent</event-label>
- <descr>
- <p>Environmental monitor status event. If enabled, this trap
- is sent when the envMonStatus indicates an error state
- ('noComm'). This trap is repeated periodically while the
- envMonStatus remains in an error state. If the envMonStatus
- returns to a non-error state ('normal'), this trap is sent
- once more with the non-error envMonStatus, and then stops
- being repeated.
- While the envMonStatus indicates an error state, all status
- traps are suppressed for the water sensor, ADC, temperature/
- humudity sensors, and contact closures on the environmental
- monitor.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- envMonID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- envMonName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- envMonStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- normal(0)
- noComm(1)
- </p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: envMonStatusEvent trap received
- systemLocation=%parm[#1]%
- envMonID=%parm[#2]%
- envMonName=%parm[#3]%
- envMonStatus=%parm[#4]%</p>
- </logmsg>
- <severity>Indeterminate</severity>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>8</mevalue>
- </maskelement>
- <varbind>
- <vbnumber>4</vbnumber>
- <vbvalue>0</vbvalue>
- </varbind>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/envMonWaterSensorEvent-Normal</uei>
- <event-label>Sentry3-MIB defined trap event: envMonWaterSensorEvent-Normal</event-label>
- <descr>
- <p>Environmental monitor water sensor event. If enabled, this
- trap is sent when the envMonWaterSensorStatus indicates an
- error state ('alarm'). This trap is repeated periodically
- while the envMonWaterSensorStatus remains in an error state.
- If the envMonWaterSensorStatus returns to a non-error state
- ('normal'), this trap is sent once more with the non-error
- envMonWaterSensorStatus, and then stops being repeated.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- envMonID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- envMonWaterSensorName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- envMonWaterSensorStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- normal(0)
- alarm(1)
- noComm(2)
- </p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: envMonWaterSensorEvent normal trap received
- systemLocation=%parm[#1]%
- envMonID=%parm[#2]%
- envMonWaterSensorName=%parm[#3]%
- </logmsg>
- <severity>Normal</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[#2]%:%parm[#3]%" alarm-type="2" clear-key="uei.opennms.org/vendor/ServerTech/traps/envMonWaterSensorEvent-Error:%dpname%:%nodeid%:%interface%:%parm[#2]%i:%parm[#3]%" auto-clean="false"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>8</mevalue>
- </maskelement>
- <varbind>
- <vbnumber>4</vbnumber>
- <vbvalue>1</vbvalue>
- </varbind>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/envMonWaterSensorEvent-Error</uei>
- <event-label>Sentry3-MIB defined trap event: envMonWaterSensorEvent-Error</event-label>
- <descr>
- <p>Environmental monitor water sensor event. If enabled, this
- trap is sent when the envMonWaterSensorStatus indicates an
- error state ('alarm'). This trap is repeated periodically
- while the envMonWaterSensorStatus remains in an error state.
- If the envMonWaterSensorStatus returns to a non-error state
- ('normal'), this trap is sent once more with the non-error
- envMonWaterSensorStatus, and then stops being repeated.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- envMonID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- envMonWaterSensorName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- envMonWaterSensorStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- normal(0)
- alarm(1)
- noComm(2)
- </p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: envMonWaterSensorEvent error trap received
- systemLocation=%parm[#1]%
- envMonID=%parm[#2]%
- envMonWaterSensorName=%parm[#3]%
- </logmsg>
- <severity>Minor</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[#2]%:%parm[#3]%" alarm-type="1" auto-clean="false"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>8</mevalue>
- </maskelement>
- <varbind>
- <vbnumber>4</vbnumber>
- <vbvalue>0</vbvalue>
- </varbind>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/envMonWaterSensorEvent-Error</uei>
- <event-label>Sentry3-MIB defined trap event: envMonWaterSensorEvent-Error</event-label>
- <descr>
- <p>Environmental monitor water sensor event. If enabled, this
- trap is sent when the envMonWaterSensorStatus indicates an
- error state ('alarm'). This trap is repeated periodically
- while the envMonWaterSensorStatus remains in an error state.
- If the envMonWaterSensorStatus returns to a non-error state
- ('normal'), this trap is sent once more with the non-error
- envMonWaterSensorStatus, and then stops being repeated.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- envMonID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- envMonWaterSensorName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- envMonWaterSensorStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- normal(0)
- alarm(1)
- noComm(2)
- </p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: envMonWaterSensorEvent noComm trap received
- systemLocation=%parm[#1]%
- envMonID=%parm[#2]%
- envMonWaterSensorName=%parm[#3]%
- </logmsg>
- <severity>Minor</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[#2]%:%parm[#3]%" alarm-type="1" auto-clean="false"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>8</mevalue>
- </maskelement>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/envMonWaterSensorEvent</uei>
- <event-label>Sentry3-MIB defined trap event: envMonWaterSensorEvent</event-label>
- <descr>
- <p>Environmental monitor water sensor event. If enabled, this
- trap is sent when the envMonWaterSensorStatus indicates an
- error state ('alarm'). This trap is repeated periodically
- while the envMonWaterSensorStatus remains in an error state.
- If the envMonWaterSensorStatus returns to a non-error state
- ('normal'), this trap is sent once more with the non-error
- envMonWaterSensorStatus, and then stops being repeated.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- envMonID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- envMonWaterSensorName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- envMonWaterSensorStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- normal(0)
- alarm(1)
- noComm(2)
- </p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: envMonWaterSensorEvent trap received
- systemLocation=%parm[#1]%
- envMonID=%parm[#2]%
- envMonWaterSensorName=%parm[#3]%
- envMonWaterSensorStatus=%parm[#4]%</p>
- </logmsg>
- <severity>Indeterminate</severity>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>9</mevalue>
- </maskelement>
- <varbind>
- <vbnumber>4</vbnumber>
- <vbvalue>0</vbvalue>
- </varbind>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/envMonADCEvent-Normal</uei>
- <event-label>Sentry3-MIB defined trap event: envMonADCEvent-Normal</event-label>
- <descr>
- <p>Environmental monitor analog-to-digital converter event.
- If enabled, this trap is sent when the envMonADCStatus
- indicates an error state ('countLow' or 'countHigh'). This
- trap is repeated periodically while the envMonADCStatus
- remains in an error state. If the envMonADCStatus returns
- to a non-error state ('normal'), this trap is sent once more
- with the non-error envMonADCStatus, and then stops being
- repeated.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- envMonID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- envMonADCName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- envMonADCStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- normal(0)
- reading(1)
- countLow(2)
- countHigh(3)
- readError(4)
- noComm(5)
- </p></td></tr>
- <tr><td><b>
- envMonADCCount</b></td><td>
- %parm[#5]%;</td><td><p></p></td></tr>
- <tr><td><b>
- envMonADCLowThresh</b></td><td>
- %parm[#6]%;</td><td><p></p></td></tr>
- <tr><td><b>
- envMonADCHighThresh</b></td><td>
- %parm[#7]%;</td><td><p></p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: envMonADCEvent normal trap received
- systemLocation=%parm[#1]%
- envMonID=%parm[#2]%
- envMonADCName=%parm[#3]%
- </logmsg>
- <severity>Normal</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[#2]%:%parm[#3]%" alarm-type="2" clear-key="uei.opennms.org/vendor/ServerTech/traps/envMonADCEvent-Error:%dpname%:%nodeid%:%interface%:%parm[#2]%i:%parm[#3]%" auto-clean="false"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>9</mevalue>
- </maskelement>
- <varbind>
- <vbnumber>4</vbnumber>
- <vbvalue>1</vbvalue>
- </varbind>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/envMonADCEvent-Error</uei>
- <event-label>Sentry3-MIB defined trap event: envMonADCEvent-Error</event-label>
- <descr>
- <p>Environmental monitor analog-to-digital converter event.
- If enabled, this trap is sent when the envMonADCStatus
- indicates an error state ('countLow' or 'countHigh'). This
- trap is repeated periodically while the envMonADCStatus
- remains in an error state. If the envMonADCStatus returns
- to a non-error state ('normal'), this trap is sent once more
- with the non-error envMonADCStatus, and then stops being
- repeated.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- envMonID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- envMonADCName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- envMonADCStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- normal(0)
- reading(1)
- countLow(2)
- countHigh(3)
- readError(4)
- noComm(5)
- </p></td></tr>
- <tr><td><b>
- envMonADCCount</b></td><td>
- %parm[#5]%;</td><td><p></p></td></tr>
- <tr><td><b>
- envMonADCLowThresh</b></td><td>
- %parm[#6]%;</td><td><p></p></td></tr>
- <tr><td><b>
- envMonADCHighThresh</b></td><td>
- %parm[#7]%;</td><td><p></p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: envMonADCEvent reading trap received
- systemLocation=%parm[#1]%
- envMonID=%parm[#2]%
- envMonADCName=%parm[#3]%
- </logmsg>
- <severity>Minor</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[#2]%:%parm[#3]%" alarm-type="1" auto-clean="false"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>9</mevalue>
- </maskelement>
- <varbind>
- <vbnumber>4</vbnumber>
- <vbvalue>2</vbvalue>
- </varbind>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/envMonADCEvent-Error</uei>
- <event-label>Sentry3-MIB defined trap event: envMonADCEvent-Error</event-label>
- <descr>
- <p>Environmental monitor analog-to-digital converter event.
- If enabled, this trap is sent when the envMonADCStatus
- indicates an error state ('countLow' or 'countHigh'). This
- trap is repeated periodically while the envMonADCStatus
- remains in an error state. If the envMonADCStatus returns
- to a non-error state ('normal'), this trap is sent once more
- with the non-error envMonADCStatus, and then stops being
- repeated.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- envMonID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- envMonADCName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- envMonADCStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- normal(0)
- reading(1)
- countLow(2)
- countHigh(3)
- readError(4)
- noComm(5)
- </p></td></tr>
- <tr><td><b>
- envMonADCCount</b></td><td>
- %parm[#5]%;</td><td><p></p></td></tr>
- <tr><td><b>
- envMonADCLowThresh</b></td><td>
- %parm[#6]%;</td><td><p></p></td></tr>
- <tr><td><b>
- envMonADCHighThresh</b></td><td>
- %parm[#7]%;</td><td><p></p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: envMonADCEvent countLow trap received
- systemLocation=%parm[#1]%
- envMonID=%parm[#2]%
- envMonADCName=%parm[#3]%
- </logmsg>
- <severity>Minor</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[#2]%:%parm[#3]%" alarm-type="1" auto-clean="false"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>9</mevalue>
- </maskelement>
- <varbind>
- <vbnumber>4</vbnumber>
- <vbvalue>3</vbvalue>
- </varbind>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/envMonADCEvent-Error</uei>
- <event-label>Sentry3-MIB defined trap event: envMonADCEvent-Error</event-label>
- <descr>
- <p>Environmental monitor analog-to-digital converter event.
- If enabled, this trap is sent when the envMonADCStatus
- indicates an error state ('countLow' or 'countHigh'). This
- trap is repeated periodically while the envMonADCStatus
- remains in an error state. If the envMonADCStatus returns
- to a non-error state ('normal'), this trap is sent once more
- with the non-error envMonADCStatus, and then stops being
- repeated.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- envMonID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- envMonADCName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- envMonADCStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- normal(0)
- reading(1)
- countLow(2)
- countHigh(3)
- readError(4)
- noComm(5)
- </p></td></tr>
- <tr><td><b>
- envMonADCCount</b></td><td>
- %parm[#5]%;</td><td><p></p></td></tr>
- <tr><td><b>
- envMonADCLowThresh</b></td><td>
- %parm[#6]%;</td><td><p></p></td></tr>
- <tr><td><b>
- envMonADCHighThresh</b></td><td>
- %parm[#7]%;</td><td><p></p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: envMonADCEvent countHigh trap received
- systemLocation=%parm[#1]%
- envMonID=%parm[#2]%
- envMonADCName=%parm[#3]%
- </logmsg>
- <severity>Minor</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[#2]%:%parm[#3]%" alarm-type="1" auto-clean="false"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>9</mevalue>
- </maskelement>
- <varbind>
- <vbnumber>4</vbnumber>
- <vbvalue>4</vbvalue>
- </varbind>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/envMonADCEvent-Error</uei>
- <event-label>Sentry3-MIB defined trap event: envMonADCEvent-Error</event-label>
- <descr>
- <p>Environmental monitor analog-to-digital converter event.
- If enabled, this trap is sent when the envMonADCStatus
- indicates an error state ('countLow' or 'countHigh'). This
- trap is repeated periodically while the envMonADCStatus
- remains in an error state. If the envMonADCStatus returns
- to a non-error state ('normal'), this trap is sent once more
- with the non-error envMonADCStatus, and then stops being
- repeated.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- envMonID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- envMonADCName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- envMonADCStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- normal(0)
- reading(1)
- countLow(2)
- countHigh(3)
- readError(4)
- noComm(5)
- </p></td></tr>
- <tr><td><b>
- envMonADCCount</b></td><td>
- %parm[#5]%;</td><td><p></p></td></tr>
- <tr><td><b>
- envMonADCLowThresh</b></td><td>
- %parm[#6]%;</td><td><p></p></td></tr>
- <tr><td><b>
- envMonADCHighThresh</b></td><td>
- %parm[#7]%;</td><td><p></p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: envMonADCEvent readError trap received
- systemLocation=%parm[#1]%
- envMonID=%parm[#2]%
- envMonADCName=%parm[#3]%
- </logmsg>
- <severity>Minor</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[#2]%:%parm[#3]%" alarm-type="1" auto-clean="false"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>9</mevalue>
- </maskelement>
- <varbind>
- <vbnumber>4</vbnumber>
- <vbvalue>5</vbvalue>
- </varbind>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/envMonADCEvent-Error</uei>
- <event-label>Sentry3-MIB defined trap event: envMonADCEvent-Error</event-label>
- <descr>
- <p>Environmental monitor analog-to-digital converter event.
- If enabled, this trap is sent when the envMonADCStatus
- indicates an error state ('countLow' or 'countHigh'). This
- trap is repeated periodically while the envMonADCStatus
- remains in an error state. If the envMonADCStatus returns
- to a non-error state ('normal'), this trap is sent once more
- with the non-error envMonADCStatus, and then stops being
- repeated.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- envMonID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- envMonADCName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- envMonADCStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- normal(0)
- reading(1)
- countLow(2)
- countHigh(3)
- readError(4)
- noComm(5)
- </p></td></tr>
- <tr><td><b>
- envMonADCCount</b></td><td>
- %parm[#5]%;</td><td><p></p></td></tr>
- <tr><td><b>
- envMonADCLowThresh</b></td><td>
- %parm[#6]%;</td><td><p></p></td></tr>
- <tr><td><b>
- envMonADCHighThresh</b></td><td>
- %parm[#7]%;</td><td><p></p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: envMonADCEvent noComm trap received
- systemLocation=%parm[#1]%
- envMonID=%parm[#2]%
- envMonADCName=%parm[#3]%
- </logmsg>
- <severity>Minor</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[#2]%:%parm[#3]%" alarm-type="1" auto-clean="false"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>9</mevalue>
- </maskelement>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/envMonADCEvent</uei>
- <event-label>Sentry3-MIB defined trap event: envMonADCEvent</event-label>
- <descr>
- <p>Environmental monitor analog-to-digital converter event.
- If enabled, this trap is sent when the envMonADCStatus
- indicates an error state ('countLow' or 'countHigh'). This
- trap is repeated periodically while the envMonADCStatus
- remains in an error state. If the envMonADCStatus returns
- to a non-error state ('normal'), this trap is sent once more
- with the non-error envMonADCStatus, and then stops being
- repeated.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- envMonID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- envMonADCName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- envMonADCStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- normal(0)
- reading(1)
- countLow(2)
- countHigh(3)
- readError(4)
- noComm(5)
- </p></td></tr>
- <tr><td><b>
- envMonADCCount</b></td><td>
- %parm[#5]%;</td><td><p></p></td></tr>
- <tr><td><b>
- envMonADCLowThresh</b></td><td>
- %parm[#6]%;</td><td><p></p></td></tr>
- <tr><td><b>
- envMonADCHighThresh</b></td><td>
- %parm[#7]%;</td><td><p></p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: envMonADCEvent trap received
- systemLocation=%parm[#1]%
- envMonID=%parm[#2]%
- envMonADCName=%parm[#3]%
- envMonADCStatus=%parm[#4]%
- envMonADCCount=%parm[#5]%
- envMonADCLowThresh=%parm[#6]%
- envMonADCHighThresh=%parm[#7]%</p>
- </logmsg>
- <severity>Indeterminate</severity>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>10</mevalue>
- </maskelement>
- <varbind>
- <vbnumber>4</vbnumber>
- <vbvalue>0</vbvalue>
- </varbind>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/tempHumidSensorStatusEvent-Normal</uei>
- <event-label>Sentry3-MIB defined trap event: tempHumidSensorStatusEvent-Normal</event-label>
- <descr>
- <p>Temperature/humidity sensor status event. If enabled, this
- trap is sent when the tempHumidSensorStatus indicates an
- error state ('lost'). This trap is repeated periodically
- while the tempHumidSensorStatus remains in an error state.
- If the tempHumidSensorStatus returns to a non-error state
- ('found'), this trap is sent once more with the non-error
- tempHumidSensorStatus, and then stops being repeated.
- While the tempHumidSensorStatus indicates an error state, all
- temperature and humidity status traps are suppressed for the
- temperature/humudity sensor.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- found(0)
- notFound(1)
- lost(2)
- noComm(3)
- </p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: tempHumidSensorStatusEvent found trap received
- systemLocation=%parm[#1]%
- tempHumidSensorID=%parm[#2]%
- tempHumidSensorName=%parm[#3]%
- </logmsg>
- <severity>Normal</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[#2]%:%parm[#3]%" alarm-type="2" clear-key="uei.opennms.org/vendor/ServerTech/traps/tempHumidSensorStatusEvent-Error:%dpname%:%nodeid%:%interface%:%parm[#2]%i:%parm[#3]%" auto-clean="false"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>10</mevalue>
- </maskelement>
- <varbind>
- <vbnumber>4</vbnumber>
- <vbvalue>1</vbvalue>
- </varbind>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/tempHumidSensorStatusEvent-Normal</uei>
- <event-label>Sentry3-MIB defined trap event: tempHumidSensorStatusEvent-Normal</event-label>
- <descr>
- <p>Temperature/humidity sensor status event. If enabled, this
- trap is sent when the tempHumidSensorStatus indicates an
- error state ('lost'). This trap is repeated periodically
- while the tempHumidSensorStatus remains in an error state.
- If the tempHumidSensorStatus returns to a non-error state
- ('found'), this trap is sent once more with the non-error
- tempHumidSensorStatus, and then stops being repeated.
- While the tempHumidSensorStatus indicates an error state, all
- temperature and humidity status traps are suppressed for the
- temperature/humudity sensor.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- found(0)
- notFound(1)
- lost(2)
- noComm(3)
- </p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: tempHumidSensorStatusEvent not found trap received
- systemLocation=%parm[#1]%
- tempHumidSensorID=%parm[#2]%
- tempHumidSensorName=%parm[#3]%
- </logmsg>
- <severity>Normal</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[#2]%:%parm[#3]%" alarm-type="2" clear-key="uei.opennms.org/vendor/ServerTech/traps/tempHumidSensorStatusEvent-Error:%dpname%:%nodeid%:%interface%:%parm[#2]%i:%parm[#3]%" auto-clean="false"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>10</mevalue>
- </maskelement>
- <varbind>
- <vbnumber>4</vbnumber>
- <vbvalue>2</vbvalue>
- </varbind>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/tempHumidSensorStatusEvent-Error</uei>
- <event-label>Sentry3-MIB defined trap event: tempHumidSensorStatusEvent-Error</event-label>
- <descr>
- <p>Temperature/humidity sensor status event. If enabled, this
- trap is sent when the tempHumidSensorStatus indicates an
- error state ('lost'). This trap is repeated periodically
- while the tempHumidSensorStatus remains in an error state.
- If the tempHumidSensorStatus returns to a non-error state
- ('found'), this trap is sent once more with the non-error
- tempHumidSensorStatus, and then stops being repeated.
- While the tempHumidSensorStatus indicates an error state, all
- temperature and humidity status traps are suppressed for the
- temperature/humudity sensor.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- found(0)
- notFound(1)
- lost(2)
- noComm(3)
- </p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: tempHumidSensorStatusEvent lost trap received
- systemLocation=%parm[#1]%
- tempHumidSensorID=%parm[#2]%
- tempHumidSensorName=%parm[#3]%
- </logmsg>
- <severity>Minor</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[#2]%:%parm[#3]%" alarm-type="1" auto-clean="false"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>10</mevalue>
- </maskelement>
- <varbind>
- <vbnumber>4</vbnumber>
- <vbvalue>3</vbvalue>
- </varbind>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/tempHumidSensorStatusEvent-Error</uei>
- <event-label>Sentry3-MIB defined trap event: tempHumidSensorStatusEvent-Error</event-label>
- <descr>
- <p>Temperature/humidity sensor status event. If enabled, this
- trap is sent when the tempHumidSensorStatus indicates an
- error state ('lost'). This trap is repeated periodically
- while the tempHumidSensorStatus remains in an error state.
- If the tempHumidSensorStatus returns to a non-error state
- ('found'), this trap is sent once more with the non-error
- tempHumidSensorStatus, and then stops being repeated.
- While the tempHumidSensorStatus indicates an error state, all
- temperature and humidity status traps are suppressed for the
- temperature/humudity sensor.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- found(0)
- notFound(1)
- lost(2)
- noComm(3)
- </p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: tempHumidSensorStatusEvent noComm trap received
- systemLocation=%parm[#1]%
- tempHumidSensorID=%parm[#2]%
- tempHumidSensorName=%parm[#3]%
- </logmsg>
- <severity>Minor</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[#2]%:%parm[#3]%" alarm-type="1" auto-clean="false"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>10</mevalue>
- </maskelement>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/tempHumidSensorStatusEvent</uei>
- <event-label>Sentry3-MIB defined trap event: tempHumidSensorStatusEvent</event-label>
- <descr>
- <p>Temperature/humidity sensor status event. If enabled, this
- trap is sent when the tempHumidSensorStatus indicates an
- error state ('lost'). This trap is repeated periodically
- while the tempHumidSensorStatus remains in an error state.
- If the tempHumidSensorStatus returns to a non-error state
- ('found'), this trap is sent once more with the non-error
- tempHumidSensorStatus, and then stops being repeated.
- While the tempHumidSensorStatus indicates an error state, all
- temperature and humidity status traps are suppressed for the
- temperature/humudity sensor.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- found(0)
- notFound(1)
- lost(2)
- noComm(3)
- </p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: tempHumidSensorStatusEvent trap received
- systemLocation=%parm[#1]%
- tempHumidSensorID=%parm[#2]%
- tempHumidSensorName=%parm[#3]%
- tempHumidSensorStatus=%parm[#4]%</p>
- </logmsg>
- <severity>Indeterminate</severity>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>11</mevalue>
- </maskelement>
- <varbind>
- <vbnumber>4</vbnumber>
- <vbvalue>0</vbvalue>
- </varbind>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/tempHumidSensorTempEvent-Normal</uei>
- <event-label>Sentry3-MIB defined trap event: tempHumidSensorTempEvent-Normal</event-label>
- <descr>
- <p>Temperature/humidity sensor temperature event. If enabled,
- this trap is sent when the tempHumidSensorTempStatus
- indicates an error state ('tempLow' or 'tempHigh').
- This trap is repeated periodically while the
- tempHumidSensorTempStatus remains in an error state. If
- the tempHumidSensorTempStatus returns to a non-error state
- ('normal'), this trap is sent once more with the non-error
- tempHumidSensorTempStatus, and then stops being repeated.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorTempStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- normal(0)
- notFound(1)
- reading(2)
- tempLow(3)
- tempHigh(4)
- readError(5)
- lost(6)
- noComm(7)
- </p></td></tr>
- <tr><td><b>
- tempHumidSensorTempValue</b></td><td>
- %parm[#5]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorTempLowThresh</b></td><td>
- %parm[#6]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorTempHighThresh</b></td><td>
- %parm[#7]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorTempScale</b></td><td>
- %parm[#8]%;</td><td><p>
- celsius(0)
- fahrenheit(1)
- </p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: tempHumidSensorTempEvent normal trap received
- systemLocation=%parm[#1]%
- tempHumidSensorID=%parm[#2]%
- tempHumidSensorName=%parm[#3]%
- </logmsg>
- <severity>Normal</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[#2]%:%parm[#3]%" alarm-type="2" clear-key="uei.opennms.org/vendor/ServerTech/traps/tempHumidSensorTempEvent-Error:%dpname%:%nodeid%:%interface%:%parm[#2]%i:%parm[#3]%" auto-clean="false"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>11</mevalue>
- </maskelement>
- <varbind>
- <vbnumber>4</vbnumber>
- <vbvalue>1</vbvalue>
- </varbind>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/tempHumidSensorTempEvent-Normal</uei>
- <event-label>Sentry3-MIB defined trap event: tempHumidSensorTempEvent-Normal</event-label>
- <descr>
- <p>Temperature/humidity sensor temperature event. If enabled,
- this trap is sent when the tempHumidSensorTempStatus
- indicates an error state ('tempLow' or 'tempHigh').
- This trap is repeated periodically while the
- tempHumidSensorTempStatus remains in an error state. If
- the tempHumidSensorTempStatus returns to a non-error state
- ('normal'), this trap is sent once more with the non-error
- tempHumidSensorTempStatus, and then stops being repeated.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorTempStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- normal(0)
- notFound(1)
- reading(2)
- tempLow(3)
- tempHigh(4)
- readError(5)
- lost(6)
- noComm(7)
- </p></td></tr>
- <tr><td><b>
- tempHumidSensorTempValue</b></td><td>
- %parm[#5]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorTempLowThresh</b></td><td>
- %parm[#6]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorTempHighThresh</b></td><td>
- %parm[#7]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorTempScale</b></td><td>
- %parm[#8]%;</td><td><p>
- celsius(0)
- fahrenheit(1)
- </p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: tempHumidSensorTempEvent notFound trap received
- systemLocation=%parm[#1]%
- tempHumidSensorID=%parm[#2]%
- tempHumidSensorName=%parm[#3]%
- </logmsg>
- <severity>Normal</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[#2]%:%parm[#3]%" alarm-type="2" clear-key="uei.opennms.org/vendor/ServerTech/traps/tempHumidSensorTempEvent-Error:%dpname%:%nodeid%:%interface%:%parm[#2]%i:%parm[#3]%" auto-clean="false"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>11</mevalue>
- </maskelement>
- <varbind>
- <vbnumber>4</vbnumber>
- <vbvalue>2</vbvalue>
- </varbind>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/tempHumidSensorTempEvent-Error</uei>
- <event-label>Sentry3-MIB defined trap event: tempHumidSensorTempEvent-Error</event-label>
- <descr>
- <p>Temperature/humidity sensor temperature event. If enabled,
- this trap is sent when the tempHumidSensorTempStatus
- indicates an error state ('tempLow' or 'tempHigh').
- This trap is repeated periodically while the
- tempHumidSensorTempStatus remains in an error state. If
- the tempHumidSensorTempStatus returns to a non-error state
- ('normal'), this trap is sent once more with the non-error
- tempHumidSensorTempStatus, and then stops being repeated.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorTempStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- normal(0)
- notFound(1)
- reading(2)
- tempLow(3)
- tempHigh(4)
- readError(5)
- lost(6)
- noComm(7)
- </p></td></tr>
- <tr><td><b>
- tempHumidSensorTempValue</b></td><td>
- %parm[#5]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorTempLowThresh</b></td><td>
- %parm[#6]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorTempHighThresh</b></td><td>
- %parm[#7]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorTempScale</b></td><td>
- %parm[#8]%;</td><td><p>
- celsius(0)
- fahrenheit(1)
- </p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: tempHumidSensorTempEvent reading trap received
- systemLocation=%parm[#1]%
- tempHumidSensorID=%parm[#2]%
- tempHumidSensorName=%parm[#3]%
- </logmsg>
- <severity>Minor</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[#2]%:%parm[#3]%" alarm-type="1" auto-clean="false"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>11</mevalue>
- </maskelement>
- <varbind>
- <vbnumber>4</vbnumber>
- <vbvalue>3</vbvalue>
- </varbind>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/tempHumidSensorTempEvent-Error</uei>
- <event-label>Sentry3-MIB defined trap event: tempHumidSensorTempEvent-Error</event-label>
- <descr>
- <p>Temperature/humidity sensor temperature event. If enabled,
- this trap is sent when the tempHumidSensorTempStatus
- indicates an error state ('tempLow' or 'tempHigh').
- This trap is repeated periodically while the
- tempHumidSensorTempStatus remains in an error state. If
- the tempHumidSensorTempStatus returns to a non-error state
- ('normal'), this trap is sent once more with the non-error
- tempHumidSensorTempStatus, and then stops being repeated.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorTempStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- normal(0)
- notFound(1)
- reading(2)
- tempLow(3)
- tempHigh(4)
- readError(5)
- lost(6)
- noComm(7)
- </p></td></tr>
- <tr><td><b>
- tempHumidSensorTempValue</b></td><td>
- %parm[#5]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorTempLowThresh</b></td><td>
- %parm[#6]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorTempHighThresh</b></td><td>
- %parm[#7]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorTempScale</b></td><td>
- %parm[#8]%;</td><td><p>
- celsius(0)
- fahrenheit(1)
- </p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: tempHumidSensorTempEvent low temp trap received
- systemLocation=%parm[#1]%
- tempHumidSensorID=%parm[#2]%
- tempHumidSensorName=%parm[#3]%
- </logmsg>
- <severity>Minor</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[#2]%:%parm[#3]%" alarm-type="1" auto-clean="false"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>11</mevalue>
- </maskelement>
- <varbind>
- <vbnumber>4</vbnumber>
- <vbvalue>4</vbvalue>
- </varbind>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/tempHumidSensorTempEvent-Error</uei>
- <event-label>Sentry3-MIB defined trap event: tempHumidSensorTempEvent-Error</event-label>
- <descr>
- <p>Temperature/humidity sensor temperature event. If enabled,
- this trap is sent when the tempHumidSensorTempStatus
- indicates an error state ('tempLow' or 'tempHigh').
- This trap is repeated periodically while the
- tempHumidSensorTempStatus remains in an error state. If
- the tempHumidSensorTempStatus returns to a non-error state
- ('normal'), this trap is sent once more with the non-error
- tempHumidSensorTempStatus, and then stops being repeated.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorTempStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- normal(0)
- notFound(1)
- reading(2)
- tempLow(3)
- tempHigh(4)
- readError(5)
- lost(6)
- noComm(7)
- </p></td></tr>
- <tr><td><b>
- tempHumidSensorTempValue</b></td><td>
- %parm[#5]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorTempLowThresh</b></td><td>
- %parm[#6]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorTempHighThresh</b></td><td>
- %parm[#7]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorTempScale</b></td><td>
- %parm[#8]%;</td><td><p>
- celsius(0)
- fahrenheit(1)
- </p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: tempHumidSensorTempEvent high temp trap received
- systemLocation=%parm[#1]%
- tempHumidSensorID=%parm[#2]%
- tempHumidSensorName=%parm[#3]%
- </logmsg>
- <severity>Minor</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[#2]%:%parm[#3]%" alarm-type="1" auto-clean="false"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>11</mevalue>
- </maskelement>
- <varbind>
- <vbnumber>4</vbnumber>
- <vbvalue>5</vbvalue>
- </varbind>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/tempHumidSensorTempEvent-Error</uei>
- <event-label>Sentry3-MIB defined trap event: tempHumidSensorTempEvent-Error</event-label>
- <descr>
- <p>Temperature/humidity sensor temperature event. If enabled,
- this trap is sent when the tempHumidSensorTempStatus
- indicates an error state ('tempLow' or 'tempHigh').
- This trap is repeated periodically while the
- tempHumidSensorTempStatus remains in an error state. If
- the tempHumidSensorTempStatus returns to a non-error state
- ('normal'), this trap is sent once more with the non-error
- tempHumidSensorTempStatus, and then stops being repeated.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorTempStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- normal(0)
- notFound(1)
- reading(2)
- tempLow(3)
- tempHigh(4)
- readError(5)
- lost(6)
- noComm(7)
- </p></td></tr>
- <tr><td><b>
- tempHumidSensorTempValue</b></td><td>
- %parm[#5]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorTempLowThresh</b></td><td>
- %parm[#6]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorTempHighThresh</b></td><td>
- %parm[#7]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorTempScale</b></td><td>
- %parm[#8]%;</td><td><p>
- celsius(0)
- fahrenheit(1)
- </p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: tempHumidSensorTempEvent readError trap received
- systemLocation=%parm[#1]%
- tempHumidSensorID=%parm[#2]%
- tempHumidSensorName=%parm[#3]%
- </logmsg>
- <severity>Minor</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[#2]%:%parm[#3]%" alarm-type="1" auto-clean="false"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>11</mevalue>
- </maskelement>
- <varbind>
- <vbnumber>4</vbnumber>
- <vbvalue>6</vbvalue>
- </varbind>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/tempHumidSensorTempEvent-Error</uei>
- <event-label>Sentry3-MIB defined trap event: tempHumidSensorTempEvent-Error</event-label>
- <descr>
- <p>Temperature/humidity sensor temperature event. If enabled,
- this trap is sent when the tempHumidSensorTempStatus
- indicates an error state ('tempLow' or 'tempHigh').
- This trap is repeated periodically while the
- tempHumidSensorTempStatus remains in an error state. If
- the tempHumidSensorTempStatus returns to a non-error state
- ('normal'), this trap is sent once more with the non-error
- tempHumidSensorTempStatus, and then stops being repeated.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorTempStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- normal(0)
- notFound(1)
- reading(2)
- tempLow(3)
- tempHigh(4)
- readError(5)
- lost(6)
- noComm(7)
- </p></td></tr>
- <tr><td><b>
- tempHumidSensorTempValue</b></td><td>
- %parm[#5]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorTempLowThresh</b></td><td>
- %parm[#6]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorTempHighThresh</b></td><td>
- %parm[#7]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorTempScale</b></td><td>
- %parm[#8]%;</td><td><p>
- celsius(0)
- fahrenheit(1)
- </p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: tempHumidSensorTempEvent lost trap received
- systemLocation=%parm[#1]%
- tempHumidSensorID=%parm[#2]%
- tempHumidSensorName=%parm[#3]%
- </logmsg>
- <severity>Minor</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[#2]%:%parm[#3]%" alarm-type="1" auto-clean="false"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>11</mevalue>
- </maskelement>
- <varbind>
- <vbnumber>4</vbnumber>
- <vbvalue>7</vbvalue>
- </varbind>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/tempHumidSensorTempEvent-Error</uei>
- <event-label>Sentry3-MIB defined trap event: tempHumidSensorTempEvent-Error</event-label>
- <descr>
- <p>Temperature/humidity sensor temperature event. If enabled,
- this trap is sent when the tempHumidSensorTempStatus
- indicates an error state ('tempLow' or 'tempHigh').
- This trap is repeated periodically while the
- tempHumidSensorTempStatus remains in an error state. If
- the tempHumidSensorTempStatus returns to a non-error state
- ('normal'), this trap is sent once more with the non-error
- tempHumidSensorTempStatus, and then stops being repeated.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorTempStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- normal(0)
- notFound(1)
- reading(2)
- tempLow(3)
- tempHigh(4)
- readError(5)
- lost(6)
- noComm(7)
- </p></td></tr>
- <tr><td><b>
- tempHumidSensorTempValue</b></td><td>
- %parm[#5]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorTempLowThresh</b></td><td>
- %parm[#6]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorTempHighThresh</b></td><td>
- %parm[#7]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorTempScale</b></td><td>
- %parm[#8]%;</td><td><p>
- celsius(0)
- fahrenheit(1)
- </p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: tempHumidSensorTempEvent noComm trap received
- systemLocation=%parm[#1]%
- tempHumidSensorID=%parm[#2]%
- tempHumidSensorName=%parm[#3]%
- </logmsg>
- <severity>Minor</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[#2]%:%parm[#3]%" alarm-type="1" auto-clean="false"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>11</mevalue>
- </maskelement>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/tempHumidSensorTempEvent</uei>
- <event-label>Sentry3-MIB defined trap event: tempHumidSensorTempEvent</event-label>
- <descr>
- <p>Temperature/humidity sensor temperature event. If enabled,
- this trap is sent when the tempHumidSensorTempStatus
- indicates an error state ('tempLow' or 'tempHigh').
- This trap is repeated periodically while the
- tempHumidSensorTempStatus remains in an error state. If
- the tempHumidSensorTempStatus returns to a non-error state
- ('normal'), this trap is sent once more with the non-error
- tempHumidSensorTempStatus, and then stops being repeated.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorTempStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- normal(0)
- notFound(1)
- reading(2)
- tempLow(3)
- tempHigh(4)
- readError(5)
- lost(6)
- noComm(7)
- </p></td></tr>
- <tr><td><b>
- tempHumidSensorTempValue</b></td><td>
- %parm[#5]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorTempLowThresh</b></td><td>
- %parm[#6]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorTempHighThresh</b></td><td>
- %parm[#7]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorTempScale</b></td><td>
- %parm[#8]%;</td><td><p>
- celsius(0)
- fahrenheit(1)
- </p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: tempHumidSensorTempEvent trap received
- systemLocation=%parm[#1]%
- tempHumidSensorID=%parm[#2]%
- tempHumidSensorName=%parm[#3]%
- tempHumidSensorTempStatus=%parm[#4]%
- tempHumidSensorTempValue=%parm[#5]%
- tempHumidSensorTempLowThresh=%parm[#6]%
- tempHumidSensorTempHighThresh=%parm[#7]%
- tempHumidSensorTempScale=%parm[#8]%</p>
- </logmsg>
- <severity>Indeterminate</severity>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>12</mevalue>
- </maskelement>
- <varbind>
- <vbnumber>4</vbnumber>
- <vbvalue>0</vbvalue>
- </varbind>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/tempHumidSensorHumidEvent-Normal</uei>
- <event-label>Sentry3-MIB defined trap event: tempHumidSensorHumidEvent-Normal</event-label>
- <descr>
- <p>Temperature/humidity sensor humidity event. If enabled,
- this trap is sent when the tempHumidSensorHumidStatus
- indicates an error state ('humidLow' or 'humidHigh').
- This trap is repeated periodically while the
- tempHumidSensorHumidStatus remains in an error state. If
- the tempHumidSensorHumidStatus returns to a non-error state
- ('normal'), this trap is sent once more with the non-error
- tempHumidSensorHumidStatus, and then stops being repeated.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorHumidStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- normal(0)
- notFound(1)
- reading(2)
- humidLow(3)
- humidHigh(4)
- readError(5)
- lost(6)
- noComm(7)
- </p></td></tr>
- <tr><td><b>
- tempHumidSensorHumidValue</b></td><td>
- %parm[#5]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorHumidLowThresh</b></td><td>
- %parm[#6]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorHumidHighThresh</b></td><td>
- %parm[#7]%;</td><td><p></p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: tempHumidSensorHumidEvent normal trap received
- systemLocation=%parm[#1]%
- tempHumidSensorID=%parm[#2]%
- tempHumidSensorName=%parm[#3]%
- </logmsg>
- <severity>Normal</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[#2]%:%parm[#3]%" alarm-type="2" clear-key="uei.opennms.org/vendor/ServerTech/traps/tempHumidSensorHumidEvent-Error:%dpname%:%nodeid%:%interface%:%parm[#2]%i:%parm[#3]%" auto-clean="false"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>12</mevalue>
- </maskelement>
- <varbind>
- <vbnumber>4</vbnumber>
- <vbvalue>1</vbvalue>
- </varbind>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/tempHumidSensorHumidEvent-Normal</uei>
- <event-label>Sentry3-MIB defined trap event: tempHumidSensorHumidEvent-Normal</event-label>
- <descr>
- <p>Temperature/humidity sensor humidity event. If enabled,
- this trap is sent when the tempHumidSensorHumidStatus
- indicates an error state ('humidLow' or 'humidHigh').
- This trap is repeated periodically while the
- tempHumidSensorHumidStatus remains in an error state. If
- the tempHumidSensorHumidStatus returns to a non-error state
- ('normal'), this trap is sent once more with the non-error
- tempHumidSensorHumidStatus, and then stops being repeated.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorHumidStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- normal(0)
- notFound(1)
- reading(2)
- humidLow(3)
- humidHigh(4)
- readError(5)
- lost(6)
- noComm(7)
- </p></td></tr>
- <tr><td><b>
- tempHumidSensorHumidValue</b></td><td>
- %parm[#5]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorHumidLowThresh</b></td><td>
- %parm[#6]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorHumidHighThresh</b></td><td>
- %parm[#7]%;</td><td><p></p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: tempHumidSensorHumidEvent notFound trap received
- systemLocation=%parm[#1]%
- tempHumidSensorID=%parm[#2]%
- tempHumidSensorName=%parm[#3]%
- </logmsg>
- <severity>Normal</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[#2]%:%parm[#3]%" alarm-type="2" clear-key="uei.opennms.org/vendor/ServerTech/traps/tempHumidSensorHumidEvent-Error:%dpname%:%nodeid%:%interface%:%parm[#2]%i:%parm[#3]%" auto-clean="false"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>12</mevalue>
- </maskelement>
- <varbind>
- <vbnumber>4</vbnumber>
- <vbvalue>2</vbvalue>
- </varbind>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/tempHumidSensorHumidEvent-Error</uei>
- <event-label>Sentry3-MIB defined trap event: tempHumidSensorHumidEvent-Error</event-label>
- <descr>
- <p>Temperature/humidity sensor humidity event. If enabled,
- this trap is sent when the tempHumidSensorHumidStatus
- indicates an error state ('humidLow' or 'humidHigh').
- This trap is repeated periodically while the
- tempHumidSensorHumidStatus remains in an error state. If
- the tempHumidSensorHumidStatus returns to a non-error state
- ('normal'), this trap is sent once more with the non-error
- tempHumidSensorHumidStatus, and then stops being repeated.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorHumidStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- normal(0)
- notFound(1)
- reading(2)
- humidLow(3)
- humidHigh(4)
- readError(5)
- lost(6)
- noComm(7)
- </p></td></tr>
- <tr><td><b>
- tempHumidSensorHumidValue</b></td><td>
- %parm[#5]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorHumidLowThresh</b></td><td>
- %parm[#6]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorHumidHighThresh</b></td><td>
- %parm[#7]%;</td><td><p></p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: tempHumidSensorHumidEvent reading trap received
- systemLocation=%parm[#1]%
- tempHumidSensorID=%parm[#2]%
- tempHumidSensorName=%parm[#3]%
- </logmsg>
- <severity>Minor</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[#2]%:%parm[#3]%" alarm-type="1" auto-clean="false"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>12</mevalue>
- </maskelement>
- <varbind>
- <vbnumber>4</vbnumber>
- <vbvalue>3</vbvalue>
- </varbind>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/tempHumidSensorHumidEvent-Error</uei>
- <event-label>Sentry3-MIB defined trap event: tempHumidSensorHumidEvent-Error</event-label>
- <descr>
- <p>Temperature/humidity sensor humidity event. If enabled,
- this trap is sent when the tempHumidSensorHumidStatus
- indicates an error state ('humidLow' or 'humidHigh').
- This trap is repeated periodically while the
- tempHumidSensorHumidStatus remains in an error state. If
- the tempHumidSensorHumidStatus returns to a non-error state
- ('normal'), this trap is sent once more with the non-error
- tempHumidSensorHumidStatus, and then stops being repeated.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorHumidStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- normal(0)
- notFound(1)
- reading(2)
- humidLow(3)
- humidHigh(4)
- readError(5)
- lost(6)
- noComm(7)
- </p></td></tr>
- <tr><td><b>
- tempHumidSensorHumidValue</b></td><td>
- %parm[#5]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorHumidLowThresh</b></td><td>
- %parm[#6]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorHumidHighThresh</b></td><td>
- %parm[#7]%;</td><td><p></p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: tempHumidSensorHumidEvent humidLow trap received
- systemLocation=%parm[#1]%
- tempHumidSensorID=%parm[#2]%
- tempHumidSensorName=%parm[#3]%
- </logmsg>
- <severity>Minor</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[#2]%:%parm[#3]%" alarm-type="1" auto-clean="false"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>12</mevalue>
- </maskelement>
- <varbind>
- <vbnumber>4</vbnumber>
- <vbvalue>4</vbvalue>
- </varbind>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/tempHumidSensorHumidEvent-Error</uei>
- <event-label>Sentry3-MIB defined trap event: tempHumidSensorHumidEvent-Error</event-label>
- <descr>
- <p>Temperature/humidity sensor humidity event. If enabled,
- this trap is sent when the tempHumidSensorHumidStatus
- indicates an error state ('humidLow' or 'humidHigh').
- This trap is repeated periodically while the
- tempHumidSensorHumidStatus remains in an error state. If
- the tempHumidSensorHumidStatus returns to a non-error state
- ('normal'), this trap is sent once more with the non-error
- tempHumidSensorHumidStatus, and then stops being repeated.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorHumidStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- normal(0)
- notFound(1)
- reading(2)
- humidLow(3)
- humidHigh(4)
- readError(5)
- lost(6)
- noComm(7)
- </p></td></tr>
- <tr><td><b>
- tempHumidSensorHumidValue</b></td><td>
- %parm[#5]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorHumidLowThresh</b></td><td>
- %parm[#6]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorHumidHighThresh</b></td><td>
- %parm[#7]%;</td><td><p></p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: tempHumidSensorHumidEvent humidHigh trap received
- systemLocation=%parm[#1]%
- tempHumidSensorID=%parm[#2]%
- tempHumidSensorName=%parm[#3]%
- </logmsg>
- <severity>Minor</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[#2]%:%parm[#3]%" alarm-type="1" auto-clean="false"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>12</mevalue>
- </maskelement>
- <varbind>
- <vbnumber>4</vbnumber>
- <vbvalue>5</vbvalue>
- </varbind>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/tempHumidSensorHumidEvent-Error</uei>
- <event-label>Sentry3-MIB defined trap event: tempHumidSensorHumidEvent-Error</event-label>
- <descr>
- <p>Temperature/humidity sensor humidity event. If enabled,
- this trap is sent when the tempHumidSensorHumidStatus
- indicates an error state ('humidLow' or 'humidHigh').
- This trap is repeated periodically while the
- tempHumidSensorHumidStatus remains in an error state. If
- the tempHumidSensorHumidStatus returns to a non-error state
- ('normal'), this trap is sent once more with the non-error
- tempHumidSensorHumidStatus, and then stops being repeated.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorHumidStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- normal(0)
- notFound(1)
- reading(2)
- humidLow(3)
- humidHigh(4)
- readError(5)
- lost(6)
- noComm(7)
- </p></td></tr>
- <tr><td><b>
- tempHumidSensorHumidValue</b></td><td>
- %parm[#5]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorHumidLowThresh</b></td><td>
- %parm[#6]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorHumidHighThresh</b></td><td>
- %parm[#7]%;</td><td><p></p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: tempHumidSensorHumidEvent readError trap received
- systemLocation=%parm[#1]%
- tempHumidSensorID=%parm[#2]%
- tempHumidSensorName=%parm[#3]%
- </logmsg>
- <severity>Minor</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[#2]%:%parm[#3]%" alarm-type="1" auto-clean="false"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>12</mevalue>
- </maskelement>
- <varbind>
- <vbnumber>4</vbnumber>
- <vbvalue>6</vbvalue>
- </varbind>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/tempHumidSensorHumidEvent-Error</uei>
- <event-label>Sentry3-MIB defined trap event: tempHumidSensorHumidEvent-Error</event-label>
- <descr>
- <p>Temperature/humidity sensor humidity event. If enabled,
- this trap is sent when the tempHumidSensorHumidStatus
- indicates an error state ('humidLow' or 'humidHigh').
- This trap is repeated periodically while the
- tempHumidSensorHumidStatus remains in an error state. If
- the tempHumidSensorHumidStatus returns to a non-error state
- ('normal'), this trap is sent once more with the non-error
- tempHumidSensorHumidStatus, and then stops being repeated.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorHumidStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- normal(0)
- notFound(1)
- reading(2)
- humidLow(3)
- humidHigh(4)
- readError(5)
- lost(6)
- noComm(7)
- </p></td></tr>
- <tr><td><b>
- tempHumidSensorHumidValue</b></td><td>
- %parm[#5]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorHumidLowThresh</b></td><td>
- %parm[#6]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorHumidHighThresh</b></td><td>
- %parm[#7]%;</td><td><p></p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: tempHumidSensorHumidEvent lost trap received
- systemLocation=%parm[#1]%
- tempHumidSensorID=%parm[#2]%
- tempHumidSensorName=%parm[#3]%
- </logmsg>
- <severity>Minor</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[#2]%:%parm[#3]%" alarm-type="1" auto-clean="false"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>12</mevalue>
- </maskelement>
- <varbind>
- <vbnumber>4</vbnumber>
- <vbvalue>7</vbvalue>
- </varbind>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/tempHumidSensorHumidEvent-Error</uei>
- <event-label>Sentry3-MIB defined trap event: tempHumidSensorHumidEvent-Error</event-label>
- <descr>
- <p>Temperature/humidity sensor humidity event. If enabled,
- this trap is sent when the tempHumidSensorHumidStatus
- indicates an error state ('humidLow' or 'humidHigh').
- This trap is repeated periodically while the
- tempHumidSensorHumidStatus remains in an error state. If
- the tempHumidSensorHumidStatus returns to a non-error state
- ('normal'), this trap is sent once more with the non-error
- tempHumidSensorHumidStatus, and then stops being repeated.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorHumidStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- normal(0)
- notFound(1)
- reading(2)
- humidLow(3)
- humidHigh(4)
- readError(5)
- lost(6)
- noComm(7)
- </p></td></tr>
- <tr><td><b>
- tempHumidSensorHumidValue</b></td><td>
- %parm[#5]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorHumidLowThresh</b></td><td>
- %parm[#6]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorHumidHighThresh</b></td><td>
- %parm[#7]%;</td><td><p></p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: tempHumidSensorHumidEvent noComm trap received
- systemLocation=%parm[#1]%
- tempHumidSensorID=%parm[#2]%
- tempHumidSensorName=%parm[#3]%
- </logmsg>
- <severity>Minor</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[#2]%:%parm[#3]%" alarm-type="1" auto-clean="false"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>12</mevalue>
- </maskelement>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/tempHumidSensorHumidEvent</uei>
- <event-label>Sentry3-MIB defined trap event: tempHumidSensorHumidEvent</event-label>
- <descr>
- <p>Temperature/humidity sensor humidity event. If enabled,
- this trap is sent when the tempHumidSensorHumidStatus
- indicates an error state ('humidLow' or 'humidHigh').
- This trap is repeated periodically while the
- tempHumidSensorHumidStatus remains in an error state. If
- the tempHumidSensorHumidStatus returns to a non-error state
- ('normal'), this trap is sent once more with the non-error
- tempHumidSensorHumidStatus, and then stops being repeated.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorHumidStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- normal(0)
- notFound(1)
- reading(2)
- humidLow(3)
- humidHigh(4)
- readError(5)
- lost(6)
- noComm(7)
- </p></td></tr>
- <tr><td><b>
- tempHumidSensorHumidValue</b></td><td>
- %parm[#5]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorHumidLowThresh</b></td><td>
- %parm[#6]%;</td><td><p></p></td></tr>
- <tr><td><b>
- tempHumidSensorHumidHighThresh</b></td><td>
- %parm[#7]%;</td><td><p></p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: tempHumidSensorHumidEvent trap received
- systemLocation=%parm[#1]%
- tempHumidSensorID=%parm[#2]%
- tempHumidSensorName=%parm[#3]%
- tempHumidSensorHumidStatus=%parm[#4]%
- tempHumidSensorHumidValue=%parm[#5]%
- tempHumidSensorHumidLowThresh=%parm[#6]%
- tempHumidSensorHumidHighThresh=%parm[#7]%</p>
- </logmsg>
- <severity>Indeterminate</severity>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>13</mevalue>
- </maskelement>
- <varbind>
- <vbnumber>4</vbnumber>
- <vbvalue>0</vbvalue>
- </varbind>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/contactClosureEvent-Normal</uei>
- <event-label>Sentry3-MIB defined trap event: contactClosureEvent-Normal</event-label>
- <descr>
- <p>Contact closure event. If enabled, this trap is sent when
- the contactClosureStatus indicates an error state ('alarm').
- This trap is repeated periodically while the
- contactClosureStatus remains in an error state. If the
- contactClosureStatus returns to a non-error state ('normal'),
- this trap is sent once more with the non-error
- contactClosureStatus, and then stops being repeated.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- contactClosureID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- contactClosureName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- contactClosureStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- normal(0)
- alarm(1)
- noComm(2)
- </p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: contactClosureEvent normal trap received
- systemLocation=%parm[#1]%
- contactClosureID=%parm[#2]%
- contactClosureName=%parm[#3]%
- </logmsg>
- <severity>Normal</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[#2]%:%parm[#3]%" alarm-type="2" clear-key="uei.opennms.org/vendor/ServerTech/traps/contactClosureEvent-Error:%dpname%:%nodeid%:%interface%:%parm[#2]%i:%parm[#3]%" auto-clean="false"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>13</mevalue>
- </maskelement>
- <varbind>
- <vbnumber>4</vbnumber>
- <vbvalue>1</vbvalue>
- </varbind>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/contactClosureEvent-Error</uei>
- <event-label>Sentry3-MIB defined trap event: contactClosureEvent-Error</event-label>
- <descr>
- <p>Contact closure event. If enabled, this trap is sent when
- the contactClosureStatus indicates an error state ('alarm').
- This trap is repeated periodically while the
- contactClosureStatus remains in an error state. If the
- contactClosureStatus returns to a non-error state ('normal'),
- this trap is sent once more with the non-error
- contactClosureStatus, and then stops being repeated.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- contactClosureID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- contactClosureName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- contactClosureStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- normal(0)
- alarm(1)
- noComm(2)
- </p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: contactClosureEvent alarm trap received
- systemLocation=%parm[#1]%
- contactClosureID=%parm[#2]%
- contactClosureName=%parm[#3]%
- </logmsg>
- <severity>Minor</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[#2]%:%parm[#3]%" alarm-type="1" auto-clean="false"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>13</mevalue>
- </maskelement>
- <varbind>
- <vbnumber>4</vbnumber>
- <vbvalue>2</vbvalue>
- </varbind>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/contactClosureEvent-Error</uei>
- <event-label>Sentry3-MIB defined trap event: contactClosureEvent-Error</event-label>
- <descr>
- <p>Contact closure event. If enabled, this trap is sent when
- the contactClosureStatus indicates an error state ('alarm').
- This trap is repeated periodically while the
- contactClosureStatus remains in an error state. If the
- contactClosureStatus returns to a non-error state ('normal'),
- this trap is sent once more with the non-error
- contactClosureStatus, and then stops being repeated.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- contactClosureID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- contactClosureName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- contactClosureStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- normal(0)
- alarm(1)
- noComm(2)
- </p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: contactClosureEvent noComm trap received
- systemLocation=%parm[#1]%
- contactClosureID=%parm[#2]%
- contactClosureName=%parm[#3]%
- </logmsg>
- <severity>Minor</severity>
- <alarm-data reduction-key="%uei%:%dpname%:%nodeid%:%interface%:%parm[#2]%:%parm[#3]%" alarm-type="1" auto-clean="false"/>
- </event>
- <event>
- <mask>
- <maskelement>
- <mename>id</mename>
- <mevalue>.1.3.6.1.4.1.1718.3.100</mevalue>
- </maskelement>
- <maskelement>
- <mename>generic</mename>
- <mevalue>6</mevalue>
- </maskelement>
- <maskelement>
- <mename>specific</mename>
- <mevalue>13</mevalue>
- </maskelement>
- </mask>
- <uei>uei.opennms.org/vendor/ServerTech/traps/contactClosureEvent</uei>
- <event-label>Sentry3-MIB defined trap event: contactClosureEvent</event-label>
- <descr>
- <p>Contact closure event. If enabled, this trap is sent when
- the contactClosureStatus indicates an error state ('alarm').
- This trap is repeated periodically while the
- contactClosureStatus remains in an error state. If the
- contactClosureStatus returns to a non-error state ('normal'),
- this trap is sent once more with the non-error
- contactClosureStatus, and then stops being repeated.</p><table>
- <tr><td><b>
- systemLocation</b></td><td>
- %parm[#1]%;</td><td><p></p></td></tr>
- <tr><td><b>
- contactClosureID</b></td><td>
- %parm[#2]%;</td><td><p></p></td></tr>
- <tr><td><b>
- contactClosureName</b></td><td>
- %parm[#3]%;</td><td><p></p></td></tr>
- <tr><td><b>
- contactClosureStatus</b></td><td>
- %parm[#4]%;</td><td><p>
- normal(0)
- alarm(1)
- noComm(2)
- </p></td></tr></table>
- </descr>
- <logmsg dest='logndisplay'><p>
- Sentry Event: contactClosureEvent trap received
- systemLocation=%parm[#1]%
- contactClosureID=%parm[#2]%
- contactClosureName=%parm[#3]%
- contactClosureStatus=%parm[#4]%</p>
- </logmsg>
- <severity>Indeterminate</severity>
- </event>
- </events>
- <!-- End of auto generated data from MIB: Sentry3-MIB -->